beautypg.com

Message priority (prior - 1) 33, Blinking message (blnk-yes/no) 33, Multiplex (mux - yes/no) 33 – Red Lion LEGEND User Manual

Page 35: Maintained/momentary message request 33, Message cancellation 33, Message time 33, Message color 33

background image

MESSAGE PRIORITY (PRIOR - 1)

Messages can be assigned a priority from 1 to 8 (1 = highest priority).

Messages of equal or higher priority will supersede or replace a displayed
message of lower or equal priority.

BLINKING MESSAGE (BLNK-YES/NO)

This parameter enables the message to blink at a one second rate when

displayed. This mode is only available with 1 or 2 line block messages.

MULTIPLEX (MUX - YES/NO)

Allows a message to be multiplexed with the indication display. The unit

displays the requested message then the indication display each for 2 seconds.
Message multiplexing is only available with 1 or 2 line block messages.

MAINTAINED/MOMENTARY MESSAGE REQUEST
Maintained Request (MNT. REQ)

Programming a message for maintained request allows the message to be

re-requested if the message has been displaced by another message. To be
re-requested, the User Input or output requesting the message must be active
(maintained) and the interrupting message must have been cancelled.

Maintained messages of the same priority are treated as follows when more

than one message requesting input or output is active. A new message of the same
or higher priority will always be requested when the request source is activated.
When a maintained message is cancelled, the message of the requesting input or
output of highest priority is displayed. The priority order, from highest to lowest,
for the various request sources are: User Input 1, 2, 3, 4, User F1, User F2, Binary
Message Request inputs, and Outputs 1 to 4. User Input 1 (programmed for
REQ.MSG) has the highest priority and Output 4 has the lowest.

Momentary Request (MOM. REQ)

Once a momentary message is displayed, if another message is requested and

displaces the momentary message, the momentary message is cancelled. It will not
be requested again unless the User Input or output is deactivated then activated
again. If no other messages are requested while the momentary message is
displayed, it remains on the display until cancelled as programmed.

MESSAGE CANCELLATION

Any displayed message is immediately displaced when another message of

equal or higher priority is requested. A displayed message can also be cancelled
by activating a User Input programmed for the Cancel Message function, or via
the serial port. If no other function purposely cancels a message, it is cancelled
per the cancellation mode programmed. A message that is programmed for
maintained request will be re-requested when the message times out or is
cancelled, if the request source (User Input or output) is still active. If several
maintained messages’ request sources are active, and the last requested message
times out or is cancelled, the message associated with the highest priority input
will be requested next (See Maintained Request).
LATCHED - Latched messages can only be cancelled by the methods

described above.

TIMED - Timed messages automatically cancel at the end of the specified time

period as programmed in “MESSAGE TIME”. A Character or block scrolling
message will scroll to the end before being cancelled. This causes the message
to remain on the display longer than specified by the time-out value. A 2 Line
Block message will stay on the display for a minimum of 2 sec. (1 block time)
before timing out. The message time out value is initially set to 5 seconds when
the timed mode is selected.

TIL END - A message programmed for this mode will automatically get

cancelled when the output or User Input programmed to request this particular
message deactivates. Only one request source should be programmed to
request a message set for Til End. A Til End message that is requested by serial
communication will be immediately cancelled, if there is an inactive request
source set to request that message.

MESSAGE TIME

This parameter is available only if the message cancellation mode is set for timed.

The message time for a timed message can be programmed from 1 to 599 seconds.

MESSAGE COLOR

Can be programmed for Red or Green on dual color models.

-33-