beautypg.com

Ag Leader EZ-Guide 500 Variable Rate Getting Started Guide User Manual

Page 8

background image

After the field is selected, the Available Prescriptions List screen appears.

To load a prescription:

Press

or

to select the prescription to load.

1.

Note: To continue without loading a prescription, select None.

Press

. The Prescription Parameters screen appears.

2.

Press

to configure the prescription setup:

3.

ITEM

DESCRIPTION

Rate Column

Column in the prescription .dbf file containing the rate information.

Rate Units

Units that the application rate information is stored in.
Note: For Raven and Rawson controllers, the only option for Rate Units is Custom.

Scale Factor

Applied to the rate information to scale the application. For example, to apply half or double
the specified appliation rate.

Rate Outside
Polygon

Rate applied when the vehicle moves to an area not covered by an application rate polygon.
There are two options:
* Zero − a zero rate will be sent to the controller
* Last rate − keep applying the last rate

Select Continue and press

.

4.

The prescription is loaded.

To change the prescription while in the field, you must reload the current AB line:

6