ITEM
DESCRIPTION
1
The actual current rate
Note: Since the Hardi controller does not report the actual applied rate to the EZ−Guide 500
lightbar, this item will always appear as N/A.
2
Auto/manual switching indicator shows which switching mode the controller is in.
* When the controller is in manual switching mode, the indicator is gray.
* When the controller is in automatic switching mode, the indicator is in color.
3
Fence nozzle indicator
If a fence nozzle is enabled, an indicator appears. Fence nozzle status is represented with the same
colors as the boom sections.
Note: The EZ−Guide 500 lightbar cannot automatically turn fence nozzles on or off. It only displays
the current status.
4
Boom section status indicators change color to show the current state of each boom section:
* Green − The boom section is enabled and spraying.
* Orange − The boom section is enabled but not currently spraying.
* Red − The section is off (the switch is off).
5
Application indicator. The wheel spins when the Hardi master switch is on and the booms are on.
6
The intended target rate
Note: If a prescription is loaded, P is displayed to indicate that the prescription rate is being used,
rather than the Target 1 rate ( T )
7
Application Control menu quick access icon
8
Information tab listing sprayer−specific information
Quick access icon
The icon
enables you to access the Application Control menu more quickly.
19