HP Smart Storage Administrator User Manual
Page 98

Operations 98
Error code Error message
Comment or clarification
3019
Cannot create Array - no physical disks
specified
HP SSA cannot create an array unless physical disks
are specified in the input file DRIVE parameter.
3020
SSP must be enabled in order to perform this
operation
For the specified operation, HP SSA requires SSP to
be supported and enabled.
3021
Invalid connection name
—
3022
The connectionname cannot be removed
when the hostmode has a non-default
value.
—
3023
Invalid Host Mode
—
3024
Invalid Adapter ID
—
3025
This controller does not have host mode
modification capability
—
3026
You need to have administrator rights to
continue
—
3027
Another instance of HP SSA is already
running (possibly a service). Please
terminate the HP SSA application before
running HP SSA scripting.
—
3028
Invalid Drive Cache setting. Valid options
are ENABLE and DISABLE.
—
3029
Invalid or out of order Command
Verify the ordering of the commands in the input
configuration file.
3030
Invalid or missing Array for Reconfigure
Expecting a valid array in Reconfigure mode
3031
Invalid or missing Filename for Firmware
Update
The firmware filename supplied is not a valid
filename.
3032
Firmware Update Failed
The firmware flash operation on the controller failed.
3033
This controller has been configured with a
more recent version of software. To prevent
data loss, configuration changes to this
controller are not allowed. Please upgrade
to the latest version to be able to continue to
configure this controller.
Some changes to SOULAPI are not
backward-compatible. This check prevents the use of
an older version of software on a controller
configured with a newer version, possibly overriding
changes and destroying data.
3034
Operations on this Array are temporarily
unavailable while the Array is transforming.
The user requested too many simultaneous changes.
For example, the user added new disks to an array
(expand array) and changed the size or RAID level
of logical volumes on the array. The solution is for the
user to wait until the array transformation is
complete.
3035
Invalid value for NoBatteryWriteCache
A problem exists with the
NOBATTERYWRITECACHE command. Check the
supplied argument. Not all controllers support this
operation.
3036
Cannot delete Logical Drive
A problem occurred during the attempt to delete the
specified logical drive. The drive may be in use by
the OS, it may not exist, or it may not be the last
logical drive on the array.
3038
The SplitMirror command is not valid for the
specified Array
The operation is not available. Older array
controllers/firmware may not support this command.