beautypg.com

Raid 60, Comparing the hardware-based raid methods – HP Smart Storage Administrator User Manual

Page 115

background image

Troubleshooting 115

RAID 60

RAID 60 is a nested RAID method in which the constituent hard drives are organized into several identical

RAID 6 logical drive sets (parity groups). The smallest possible RAID 60 configuration has eight drives
organized into two parity groups of four drives each.

For any given number of hard drives, data loss is least likely to occur when the drives are arranged into the

configuration that has the largest possible number of parity groups. For example, five parity groups of four

drives are more secure than four parity groups of five drives. However, less data can be stored on the array
with the larger number of parity groups.
RAID 60 is particularly useful for data archives and high-availability solutions.
Advantages:

Higher performance than for RAID 6, especially during writes.

Better fault tolerance than either RAID 0 or RAID 6.

Up to 2n physical drives can fail (where n is the number of parity groups) without loss of data, as long

as no more than two failed drives are in the same parity group.

Disadvantages:

All data is lost if a third drive in a parity group fails before one of the other failed drives in the parity
group has finished rebuilding.

A greater percentage of array capacity is used to store redundant or parity data than with non-nested
RAID methods.

Comparing the hardware-based RAID methods

Not all controllers support all RAID levels. To support some RAID levels, HP Smart Array G6 and G7

controllers require SAAP ("

About SAAP

" on page

121

).