HP Smart Storage Administrator User Manual
Page 95

Operations 95
Error code Error message
Comment or clarification
combining -reset with capture mode.
2818
Invalid Method
The method must be either Custom or Auto.
2819
Invalid Controller
An invalid controller value was specified.
2821
No controllers detected
No controllers were detected. This error applies to
Input mode only.
2823
Invalid Rebuild Priority
The specified rebuild priority is not supported.
2824
Invalid Expand Priority
The specified expand priority is not supported. This
error also occurs if the controller does not allow
expansion, and therefore does not support expand
priority.
2826
Array not specified
The Array command is missing from the script file.
Some commands were found that require an Array
to be specified.
2827
New Array ID does not match the next
available Array ID
The array ID in the script file does not match the
array ID of the next available array. For example, if
the configuration has an Array A and the input file
specifies Array C (without Array B), then the script
generates this error.
2828
New Array ID already exists
The array ID specified in the script file (in Configure
mode) already exists in the configuration. Configure
mode can only create new arrays.
2829
Cannot create Array
The controller will not allow a new array to be
created, either because the controller has no
unassigned physical drives attached or because the
maximum number of arrays or logical drives has
been reached already.
2830
Cannot expand Array
The Array could not be expanded, either because
the controller does not support expansion, or the
current configuration does not allow expansion to
occur on the array.
2831
Cannot change Array Spare
The spare state of the array could not be changed.
This error can occur when you attempt to add or
drop a spare and the current configuration does not
allow a spare state change for the array.
2832
Invalid physical drive. Possible reasons for
this include: a typing error, the drive already
exists in an array, the drive type does not
match, or it is a failed drive.
A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.
2833
Invalid Spare
A specified spare is not a valid spare drive, or it
cannot be placed in the array as a spare.
2834
Invalid logical drive
The logical drive ID is not valid.
2836
New Logical Drive ID does not match the
next available logical drive ID.
If you are attempting to replicate a
configuration that has non-consecutive
logical drive numbers, then you must
change the script file so that the logical drive
numbers are consecutive.
The script file specifies a logical drive ID that is not
the first unused ID in the sequence. For example, this
message appears if the controller has only Logical
Drive 1 and the script file specifies creation of
Logical Drive 3 (omitting Logical Drive 2). A common
cause of this error is that the input file specifies
nonsequential logical drive numbers. In this case,
change the logical drive numbers in the input file so
that they are sequential.
2837
New Logical Drive ID already exists
This error occurs in Configure mode when the logical