HP Smart Storage Administrator User Manual
Page 96
Operations 96
Error code Error message
Comment or clarification
drive ID specified in the script file already exists in
the configuration. In Configure mode, you can
create new logical drives only.
2838
Cannot create Logical Drive
The array has no free space, or the maximum
number of logical drives has been reached already.
2839
Cannot migrate Logical Drive RAID
The controller does not support RAID migration, or
migration is not possible with the current controller
configuration.
2841
Cannot extend Logical Drive
The controller does not support extension, or the
current controller configuration cannot be extended.
For example, extension is not possible if the array
has no free space.
2842
Invalid RAID
The specified RAID level is invalid or is not possible
with the current physical disk and array
configuration.
2843
Invalid Size
The specified size is invalid or is not possible with the
current configuration.
2844
Invalid Stripe Size
The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the
current configuration.
2849
Invalid ClearConfigurationWithDataLoss
parameter
The valid parameters are Yes and No (default).
2850
Controller does not support Chassis Name The controller does not support setting a chassis
name.
2851
Invalid Chassis Name
The entered chassis name is invalid. Use characters
from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +,
:, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
2852
Invalid SSP State
The requested SSP state is not a valid SSP state.
2853
Cannot change SSP settings
The SSP settings cannot be changed for the controller
or logical drive.
2854
Invalid SSP Adapter ID
The adapter ID is not a valid adapter ID that was
detected by the controller.
2857
Invalid Surface Scan Delay
—
2861
Controller does not support redundancy
settings
The controller is not redundant or does not support
redundancy settings.
2864
Invalid Preferred Path Mode
The specified value for the preferred path mode is
not valid, or the controller is not available.
2865
Invalid Preferred Path
The specified preferred path is not a valid chassis
slot for an available, active controller, or the
controller is not available.
2866
Failure opening capture file
—
2867
Failure opening input file
—
2868
Failure opening error file
—
2877
There are no suitable spares available
HP SSA found no drives that could be used as spares
for the specified array.