HP StorageWorks XP Remote Web Console Software User Manual
Page 42
Version 2 pairs after creating TrueCopy for Mainframe pairs. However, Version 2 pairs can be
created after creating TrueCopy for Mainframe pairs only when the following options are used:
•
DFSMSdss : FCTOPPRCPRIMARY
•
TSO : TGTPPRIM(YES)
•
ICKDSF : TGTOKASPPRCPRIM(YES)
•
ANTRQST Macro : TGTPPRIM(YES)
For details about using Version 2 with TrueCopy for Mainframe, see
“Using Version 2 with TrueCopy
•
TrueCopy for Mainframe program product is required for using the FlashCopy to PPRC Primary
Volume function.
•
FlashCopy to PPRC Primary Volume function can be used by TrueCopy Synchronous for
Mainframe pairs. This function can also be used for TrueCopy Asynchronous for Mainframe
pairs whose status is Suspend.
•
FlashCopy to PPRC Primary Volume function can be used when the differential data of a
TrueCopy for Mainframe pair is stored in units of tracks. This function is usually unusable when
differential data is stored in units of cylinders. See
“Comparison of Results of TrueCopy for
Mainframe Pair Operations” (page 45)
•
FlashCopy to PPRC Primary Volume function cannot be used for TrueCopy for Mainframe pairs
registered in consistency groups.
•
Data that Version 2 copies to TrueCopy for Mainframe M-VOLs are transferred to TrueCopy
for Mainframe R-VOLs asynchronously. TrueCopy for Mainframe displays the progress of this
asynchronous data transfer. Depending on the timing of the Version 2 and TrueCopy for
Mainframe copy operations, a time delay may occur between the Version 2 copy operation
and the TrueCopy for Mainframe copy operation, and the TrueCopy for Mainframe
asynchronous data transfer may progress slowly.
“Creating Version 2 Pair in TrueCopy for Mainframe Pair” (page 43)
shows the copy process of
Version 2 pairs and TrueCopy for Mainframe pairs by the FlashCopy to PPRC Primary Volume
function. shows creating a Version 2 Pair in TrueCopy for Mainframe Pair.
for Mainframe Pair in Version 2 Pair” (page 44)
shows an example of dataset copying.
42
About Version 2 Operations