Table 85 Reserved Status Variables (continued)
Description
Type
Variable
= local (SVP) timer; “None” = no timer;
“Undefined” = undefined.
Stores the consistency group number:
0x00-0x7F.
Numeric
_HrcStatus_CTG
Stores the async suspension status:
“Group” = consistency time of
String
_HrcStatus_SuspendBy
suspended volume matches consistency
time of group; “Volume” = consistency
time of suspended volume does not
match the group consistency time;
“Undefined” = undefined.
Stores the error level (async) pair
option: “Group” = all volumes in the
String
_HrcStatus_ErrLv
group will be suspended if this volume
is suspended; “Volume” = this volume
will be suspended individually;
“Undefined” = undefined.
Optional Script Parameters
The parameters outlined in
“Syntax Requirements for Optional Parameters” (page 241)
are optional
parameters that can be added to a script at the script creator's discretion. If any of these parameters
are included in a script, the HP disk array will perform a syntactical check of the script to ensure
that the syntax requirements for the parameter have been met. If no optional parameters are
included, HP disk array will not check any part of the script. HP disk array will run the script
commands based only on what has been specified in the text of the script.
for Optional Parameters” (page 241)
describes the syntax requirements that will be evaluated.
Table 86 Syntax Requirements for Optional Parameters
Syntax Requirements
Parameter
Check that each line does not exceed the maximum length
for a script statement.
Length
A phrase is enclosed by the quotation symbols.
Phrases in a script statement
Use of the parentheses is correct, and the number of
parentheses is exact.
A statement does not terminate with an equal sign.
The parameter identification name (phrase beginning with
“$”) is always defined.
The work variable and reserved variable (phrase beginning
with “_”) are always defined.
The first line begins with (Start) as an execution statement.
Script statement
The lead of one line in the execution statement always
begins with a macro name or an identification name for
non-list type work variable.
The number of phrases is correct.
Substitute statement
The equal sign is described exactly between the right side
and the left side.
The right side of the substitute statement is correct.
The number of phrases is not less than the minimum count.
SetList, AddList
Duplicate parameter identification names are not specified.
The required parameter identification name is defined.
Optional Script Parameters