specified. The maximum number of devices is 1,024. To search for more than 1,024 devices,
repeat this command for several times.
When you write device list, you can omit LDKC# if the LDKC# is 0. For example, you can
write 0x0102 when LDKC# is 0, CU# is 1, and vol# is 2.
•
Serial number list (string): RCU serial number. Default = not specific.
•
SSID number list (numeric): RCU SSID. Default = not specific.
•
Fence level list (string): “N” or “Never” = never; “S” or “Status” = status; “D” or “Data” =
data. Default = not specific.
•
Sync level list (string): “S0” or “Synchronous0” = sync, “S2” or “Synchronous2” = async.
Default = not specific.
•
Pair status list (string): “Simplex”, “Pending”, “Duplex”, “Suspended0” (suspended during
initial copy), “Suspended1” (suspended after initial copy), “Suspended” (all suspend types),
“Suspending”, “Deleting”, “Undefined”. Default = not specific.
•
Device attribute list (string): “M” or “M-Vol”, “R” or “R-Vol”. Default = not specific.
•
Error level list (string): “G” or “Group”; “V” or “Volume”. Default = not specific.
•
CT group list (numeric): consistency group number (0x00 - 0x7F). Default = not specific.
•
SEQCHK flag list (string): “Yes” = SEQCHK on; “No” = SEQCHK off. Default = not specific.
“SelectHrcDevice Command” (page 235)
provides an example of the SelectHrcDevice command
to find the pairs with the parameters listed in
“Select Device Parameters” (page 234)
.
Table 78 Select Device Parameters
Value
Parameter
_ilDevA
Output list
_ilDevB
Device list
_slWorkA
RCU serial number
_ilWorkA
RCU SSID
N
Fence level
S0, S0, S0
Copy mode
Suspended0
Pair status
M
Device attribute
234 TrueCopy for Mainframe Scripting