beautypg.com

Environmental monitoring unit, Table 3–8 emu fault code displays (continued) – HP Array Controller HSG V8.7 Software User Manual

Page 82

background image

Environmental Monitoring Unit

3–26 UltraSCSI RAID Enclosure

Fault Code 0A

No PVA is installed.

Install a PVA.

Fault Code 0B

Controller fault.

Requires an array controller-specific
action (see the array controller
documentation).

Fault Code 0C

One or more defective power supplies.

Observe all power supply status LEDs.
Replace any power supply with the
lower (power supply status) LED turned
O

FF

.

Fault Code 0D

The master enclosure SCSI bus ID
address is incorrect or an array controller
is installed in an expansion enclosure.

1.

Change the master enclosure SCSI bus ID to 0. The controllers must be RESET to recognize the
new setting.

2.

If necessary, remove the array controller from the expansion enclosure and install it in the master
enclosure.

Table 3–8

EMU Fault Code Displays (Continued)

Fault Code, Cause, Corrective

Action

EMU LED Display

1

2

3

4

5

6

7

8

CXO5769A

1

2

3

4

5

6

7

8

CXO5770A

1

2

3

4

5

6

7

8

CXO5771A

1

2

3

4

5

6

7

8

CXO5772A