Storage devices – HP Array Controller HSG V8.7 Software User Manual
Page 160
Storage Devices
7–14 UltraSCSI RAID Enclosure
11. Starting at the left end, install all the disk drive SBB devices in
shelf 4 (devices 19 through 24).
12. If performing a cold swap, determine if there are expansion
enclosures. If there are no expansion enclosures, go to step 13.
If there are expansion
enclosures, turn O
N
all the ac
input boxes for each
expansion enclosure by
pressing I on each ac power
switch (C
ALLOUT
1).
13. On the master enclosure,
turn O
N
all the ac input
boxes by pressing I on each
ac power switch
(C
ALLOUT
1).
14. Verify that the amber device fault LED is O
FF
.
Note
When the SCSI bus is active and the disk drive SBB has power,
the green device activity LED is either O
N
, F
LASHING
, or O
FF
.
The amber device fault LED is O
FF
.
Table 7–4
Installing a Disk Drive SBB (Continued)
1
0
CXO5488B
2
1