beautypg.com

Temperature fault led, Power status led, Maintenance terminal connector – HP Array Controller HSG V8.7 Software User Manual

Page 62: Blower fault leds, Power status led –6

background image

Environmental Monitoring Unit

3–6 UltraSCSI RAID Enclosure

Temperature Fault LED

If either the intake or exhaust air temperature exceeds user-defined
temperature setpoints, this amber LED (C

ALLOUT

3) turns O

N

. The

LED remains O

N

until the overtemperature condition is corrected.

Power Status LED

This green power status LED (C

ALLOUT

4) turns O

N

if all the

following normal operating conditions exist:

+5 V dc is greater than +4.7 V dc.

+12 V dc is greater than +11.4 V dc.

At least four power supplies are operational.

TERMPOWER is present on all six I/O modules.

The power status LED turns O

FF

if any one of the following error

conditions exist:

+5 V dc is less than +4.7 V dc.

+12 V dc is less than +11.4 V dc.

Fewer than four power supplies are operational.

TERMPOWER is missing from one or more I/O modules.

Maintenance Terminal Connector

This connector (C

ALLOUT

5) is used to connect the optional

maintenance terminal or a personal computer (PC) to the EMU for
displaying EMU:

Error messages

Information messages

This connector and a PC are also used to load microcode updates into
EMU memory.

Blower Fault LEDs

One or more of these eight amber blower fault LEDs (C

ALLOUT

6)

turn O

N

if one of the following error conditions exist:

One or more blowers are not operational.

One or more blowers are not operating at the correct speed.

A blower is removed.