Redundant (n+4) power supply configurations, Figure 6–6 redundant power configuration, Redundant (n+4) power supply configurations –8 – HP Array Controller HSG V8.7 Software User Manual
Page 134: Figure 6–6 redundant power configuration –8, Power distribution
Power Distribution
6–8 UltraSCSI RAID Enclosure
Any one of the following power related error conditions will cause
this UltraSCSI RAID enclosure to cease operation:
•
Loss of the ac power source
•
Failure of two shelf power supplies
•
Failure of the ac input box
Redundant (n+4) Power Supply
Configurations
This power configuration provides more power redundancy than the
standard configuration. AC power distribution is provided over both
power buses (A and B, C
ALLOUTS
1 and 2, respectively) as shown in
Figure 6–6. Each bus has four power supplies for a total of eight.
Figure 6–6
Redundant Power Configuration
AC input box A distributes the ac power through four black cords at
the left side of the enclosure. AC input box B distributes the ac power
through four grey cords on the right side of the enclosure.