beautypg.com

Sbb shelf status indicators, Power supply status leds, Figure 2–5 power supply status leds – HP Array Controller HSG V8.7 Software User Manual

Page 52: Disk drive sbb configuration, Sbb shelf status indicators –16, Figure 2–5 p

background image

Operating the UltraSCSI Enclosure

2–16 UltraSCSI RAID Enclosure

SBB Shelf Status Indicators

SBB shelf status indicators are provided by shelf power supplies and
disk drive SBBs.

Power Supply Status LEDs

The two green LEDs on each power supply (see Figure 2–5) display
the blower, the power bus, and the individual power supply status.
Normally, both these LEDs are O

N

.

Figure 2–5

Power Supply Status LEDs

The green shelf status LED (C

ALLOUT

1) is O

N

when all the power

supplies and all the blowers are operational. If any blower or power
supply fails, this LED turns O

FF

.

The green power supply status LED

(C

ALLOUT

2) is O

N

when the

power supply is operating properly. If the power supply fails, both its
power supply status LEDs turn O

FF

.

Disk Drive SBB Configuration

Part of the initial configuration procedure for the subsystem involves
configuring the disk drives. The disk drive SBB configuration tells the
array controllers the drive SBB device type, plus its physical and
logical location. The array controller requires this initial
configuration information before transferring data blocks to specific
disks to create storage sets. Once the configuration process is
complete, the system cannot function properly unless all the disks
remain in the same physical and logical location.

Figure C

ALLOUTS

1.

Shelf status LED

2.

Power supply status LED

CXO4787B

1

2