Set power cap, Set asset info, Show accounts – HP ProLiant DL170e G6 Server User Manual
Page 81: Show config, Show faults
CLI commands 81
for the enclosures and are within that zone are used to establish the minimum and maximum for the cap
to that zone.
Set power cap
•
Command:
SET POWER CAP
•
Description:
o
Establishes a power cap for all the eligible chassis that are connected to the SL-APM.
The wattage value, if provided, represents the total wattage to be allocated among all the chassis
that are part of the baseline or partial baseline if a zone, if specified. This value is divided by the
total maximum wattage established by the baseline to come up with a percentage cap value. This
percentage is then multiplied against each chassis maximum wattage value to arrive at an
appropriate cap value for that individual chassis.
o
If you specify NONE instead of a cap wattage value, then SL-APM removes all (or those in the
specified zone, if desired) of the power caps.
Set asset info
•
Command:
SET ASSETINFO [PDM1|PDM2] "
•
Description:
o
Enables SL-APM to set an asset tag. Supported only on the HP 60A PDU.
o
The
into the PDU and can be retrieved with the SHOW ASSETINFO command.
Show accounts
•
Command:
SHOW ACCOUNTS
•
Description:
Shows the existing defined accounts, including the reserved Administrator account.
Show config
•
Command:
SHOW CONFIG
•
Description:
Displays the current configuration commands for SL-APM.
Show faults
•
Command:
- ProLiant SL4540 Gen8 Server ProLiant SL160s G6 Server ProLiant SL170s G6 Server ProLiant SL165z G6 Server ProLiant SL165z G7 Server ProLiant SL335s G7 Server ProLiant SL210t Gen8 Server ProLiant SL230s Gen8 Server ProLiant SL4545 G7 Server ProLiant SL390s G7 Server ProLiant SL170z G6 Server ProLiant SL165s G7 Server ProLiant SL160z G6 Server ProLiant SL250s Gen8 Server ProLiant SL2x170z G6 Server ProLiant SL270s Gen8 Server