Setting power – HP ProLiant DL170e G6 Server User Manual
Page 51
Power capping 51
1 10 (no SL enclosure present)
2 (no Dist. Module present)
3 (no Dist. Module present)
4 (no Dist. Module present)
5 (no Dist. Module present)
6 (no Dist. Module present)
7 (no Dist. Module present)
8 (no Dist. Module present)
----- ----- -----
400 0 1007 (Totals)
50 0 125 (Averages)
Total servers = 8
Total chassis = 2
Total fan wattage = 270 (DC watts)
Total system wattage = 670 (DC watts)
Total system wattage = 743 (AC watts)
PDM Port Load
---- ---- ----
1 (no PDM Extension present)
2 (no PDM Extension present)
----
0
Setting power
Power management enables you to turn on and off single or multiple nodes within the rack.
To turn an SL server node on or off, use the SET POWER command:
SET POWER {ON|OFF|ENABLE|DISABLE} {ALL |
where:
ALL is used when the command applies to all nodes. You can also use ALL when the command applies to
all the server nodes in a particular SL server enclosure.
Extension Bar outlet number.
For example, to power on SL server node 3, enter:
SET POWER ON 2 4 3
To power off SL server node 3, enter:
SET POWER DISABLE 2 4 3
When you power on a particular SL server enclosure, you must include either the node number or ALL in the
command.
To power on the SL server nodes in the enclosure, enter:
SET POWER ON 2 4 ALL
To power on all nodes connecting to the chassis on all SL-APM Distribution Module ports, enter:
SET POWER ON ALL
- ProLiant SL4540 Gen8 Server ProLiant SL160s G6 Server ProLiant SL170s G6 Server ProLiant SL165z G6 Server ProLiant SL165z G7 Server ProLiant SL335s G7 Server ProLiant SL210t Gen8 Server ProLiant SL230s Gen8 Server ProLiant SL4545 G7 Server ProLiant SL390s G7 Server ProLiant SL170z G6 Server ProLiant SL165s G7 Server ProLiant SL160z G6 Server ProLiant SL250s Gen8 Server ProLiant SL2x170z G6 Server ProLiant SL270s Gen8 Server