Troubleshooting 72

Troubleshooting

Alert messages

The following messages appear in SL-APM.

Message

Where this issue occurs

Required action

There was an error

transferring the file,

image upgrade not

performed.

Firmware upgrade

Verify network connectivity, and then retry the

firmware upgrade.

Error upgrading

firmware image.

Firmware upgrade

Message appears with other logs describing the

actual issue. Review logs to identify, and then

resolve issue.

Dist. Module on Power

Manager Chassis port

<#> has excessive

errors and has been

marked as failed.

All modes of operation

Verify SL-APM and SL-APM Distribution Module
cabling.

Power Manager Chassis

port <#> on Dist.

Module <#> has

excessive errors and

has been marked as

failed.

All modes of operation

Verify SL-APM and SL-APM Distribution Module

cabling.

Power Manager Chassis

rendered non

functional, redundant

Power Manager Chassis

is not supported by

this firmware version.

Redundant SL-APM inserted

into SL-APM enclosure

Remove both SL-APM controllers, and then

reinsert only one controller.

The SL enclosure on

Power Manager port

<#>, Dist. Module port

<#> does not support

the Power Manager.

SL Power Management

Controller at the named

location does not support

SL-APM.

Update the SL Power Management Controller in

that chassis. If no update is available, the SL

Power Management Controller does not offer

support for SL-APM.

For messages not listed, contact HP Support (

http://www.hp.com/support

). For more information, see

"Support and other resources (on page

106

)."

Devices not discovered

If devices are not discovered, perform the following steps:

1.

Check the link and power LEDs.

2.

Check the cables.

3.

Reboot SL-APM.