Set time, Set timeout, Set power baseline – HP ProLiant DL170e G6 Server User Manual
Page 80
CLI commands 80
Set time
•
Command:
SET TIME
where:
SL-APM does not automatically adjust for Daylight Savings Time.
The time remains on this setting until you issue the RESET FACTORY command.
•
Description:
o
Sets the system time on the battery-backed clock.
o
All five parameters must be present. The hour parameter must be in 24-hour format.
Set timeout
•
Command:
SET TIMEOUT {
where:
session timeout, enter:
SET TIMEOUT 30
If you specify NONE, then no session timeouts are set. For example, enter:
SET TIMEOUT NONE
•
Description:
Sets the SSH and Telnet inactivity timeout.
Set power baseline
•
Command:
SET POWER BASELINE
•
Description:
Baseline or calibrate all servers that are connected to the SL-APM. After you have established a baseline
for the configuration, it is saved into the EEPROM on the SL-APM and the configuration monitored for
changes from the baseline configuration. Examples of changes to the configuration would include the
removal or installation of servers or chassis. If SL-APM is reset, the baseline is re-read from the EEPROM
and compared to the discovered configuration after reset.
The baseline is computed for the entire configuration and is not applicable to zones. When a power
cap is set, the baseline data establishes the minimum and maximum power values that can be used for
the cap. If you set a cap with a defined zone specified, then only that baseline data that was established
- ProLiant SL4540 Gen8 Server ProLiant SL160s G6 Server ProLiant SL170s G6 Server ProLiant SL165z G6 Server ProLiant SL165z G7 Server ProLiant SL335s G7 Server ProLiant SL210t Gen8 Server ProLiant SL230s Gen8 Server ProLiant SL4545 G7 Server ProLiant SL390s G7 Server ProLiant SL170z G6 Server ProLiant SL165s G7 Server ProLiant SL160z G6 Server ProLiant SL250s Gen8 Server ProLiant SL2x170z G6 Server ProLiant SL270s Gen8 Server