beautypg.com

Cloud bursting to savvis fails – HP Matrix Operating Environment Software User Manual

Page 225

background image

Importing a template XML file that was created in a later release of IO into a previous
release and backward compatibility

Importing a template XML file that was created in a later release of IO into a previous release of
IO displays the error: “The template is invalid and could not be read by the

Issue

IO server. The Details tab may provide more information about which part

of the template XML is invalid.”

For IO templates, backward compatibility is not supported. Forward compatibility is supported.

Cause

Create and publish templates at the earliest IO version to which they are targeted.

Action

Sporadic infrastructure orchestration designer interface failures in IE6

With IE6, launching infrastructure orchestration designer from infrastructure orchestration console
can cause sporadic infrastructure orchestration designer interface failures. Matrix OE infrastructure

Issue

orchestration console in Systems Insight Manager displays the following message: “The HP
Matrix infrastructure orchestration tool cannot be displayed.”

Possible cause

In Systems Insight Manager, select Tools

→infrastructure orchestration to return the infrastructure

orchestration console to its normal display.

Action

Cloud bursting to Savvis fails

Cloud bursting to Savvis from Matrix infrastructure orchestration only works if the IO service doesn’t
contain any data disks.

Issue

If data disks are present in the IO service design when the service is created, or if an Add Disk
operation is performed, the request will fail.

Possible cause

Remove any data disks from services attempting to be provisioned to Savvis.

Action

Linked clone provisioning of a VM template containing shared disks does not succeed

Linked clone provisioning of a VM template containing shared disks does not succeed.

Issue

During ESX server provisioning, errors similar to the following are displayed:

Possible cause

Error taking a snapshot on virtual Logical Server nnnnn

. Virtual machine

is configured to use a device that prevents the snapshot operation:

Device is a SCSI controller engaged in bus-sharing.

The VM template created from an IO template specifies linked clone servers and deploys software
as an embedded shared disk. This combination is not supported.

Perform one of the following:

Action

1. Edit the template in IO Designer and uncheck Deploy as Linked Servers.
2. Select other software to deploy without an embedded shared disk, and then retry the Create

Service operation.

Designer operations 225