Management Client elements
Additional settings:
Related cameras
Select up to 15 cameras to include in the alarm definition even if
they are not themselves triggering the alarm. This can be relevant,
for example, if you have selected an external event message (such
as a door being opened) as the source of your alarm. By defining
one or more cameras near the door, you can attach the cameras'
recordings of the incident to the alarm.
Related map
Assign a map to the alarm when it is listed in the XProtect Smart
Client's Alarm Manager.
Initial alarm owner
Select a default user responsible for the alarm.
Initial alarm priority
Select a priority (High, Medium, Low or none) for the alarm. Use
these priorities in XProtect Smart Client to determine the
importance of an alarm.
Initial alarm category
Select an alarm category for the alarm, for example
False alarm
or
Need
investigation
.
Events triggered by alarm
Define an event that the alarm can trigger in XProtect Smart Client.
Auto-close alarm
Select the check box if a particular event should close the alarm
automatically. Note that not all events can trigger alarms. Clear the
checkbox to disable the new alarm from the beginning.
Alarm Data Settings
When you configure alarm data settings, specify the following:
Alarm Data Levels tab
Priorities
Level
Add new priorities with level numbers of your choosing or use/edit
the default priority levels (numbers 1, 2 or 3). These priority levels
are used to configure the Initial alarm priority setting.
Name
Type a name for the entity. You can create as many as you like.
Sound
Select the sound to be associated with the alarm. Use one if the
default sounds or add more in Sound Settings.
States
Level
In addition to the default state levels (numbers 1, 4, 9 and 11, which
can not be edited or reused), add new states with level numbers of
your choosing. These state levels are only visible in the XProtect
Smart Client's Alarm List.
Categories
Level
Add new categories with level numbers of your choosing. These
category levels are used to configure the Initial alarm category
setting.