SHIMPO DT-601CG User Manual
Page 6
![background image](/manuals/370348/6/background.png)
2. SPECIFICATIONS
[Standard]
or pressing Shift key (when it exceeds, 999999 will be flushing)
Batch count display
Preset
Output
ITEM
SPECIFICATIONS
(depending on the mode, select reset display)
display value after reset can be chosen from -99999 to 999999
(accept NPN open collector pulse output or actual contact output)
more than 50ms.
Selectable from xxxxx
Selectable from -99999 to 999999. When delaying the secondary output,
Judge by comparing display value and preset value
During the OUT1 alarm output is on,
Output reset
Hold selection input
External
Input
Output terminal/ style
(OUT 1, 2)
Output terminal/ style
(OUT 3,4)
Output mode
1shot period
Preset operation
Preset value setting
Output display
Display Switch
Reset
Display offset
Integrated
display
Display
Accuracy
Scaling
Activate by RST key in the front part or ,
Display range is 0 to 999999 when selecting batch count operation
Selecting UP/DOWN mode, automatic reset re-output can be set.
(Change with ENT key)
: DC30V 50mA
: 0.12A Load voltage: AC140V
± 1stage, batch count and +1stage secondary output
selectable from 0.0 to 99.9. (the value outside the range is invalid)
OUT 1 LED (RED) will be synchronously flushing
making terminal reset input ON more than 50ms
Selectable from + side 2stages,
Selectable from 1shot or continuous
To activate Lap count and display change, turn the terminal block(2-3)
(accept NPN open collector pulse output or actual contact output)
Output from terminal block 9-6(OUT1) and 10-6(OUT2)
Two-points NPN open collector pulse output. Maximum rating
(6 is GND common) (However, with the line receiver, it will not function)
Output from terminal block 15-16(OUT3) and 17-18(OUT4)
Two-points PhotoMOS relay "a" contact output. Rated load current
(stabilization) output
Terminal block(4-3) to be ON more than 50ms
Select from Forbidden, Hold, Lap count, display exchange
Forbidden, Hold can be activated while terminal block(2-3) is ON. Toa
Line receiver 2 phase
However, duty is 50% (change with dip switch)
High speed input
(stabilization) output
Electric voltage pulse input (LOW<2V, HI=3.8 to 30V)
Sinusoidal input
Sine curve input
Line receiver 1phase
Selectable up to thousandth
Hit RST key in the front part or input reset at terminal block.
By setting the display offset value,
NPN open collector pulse input (minimum 10mA), or dry contact
Others
1x10
-9
to 9999 (selectable)
±0 (when the scaling is set to 1)
Six digits LED (characters are 14mm high and RED)
Display 1 : D1 LED (green) is on, Display 2 : D2 LED(green)
-99999 to 999999
3rd round stop (exceed the value three time, 999999 or -99999 will blink
Choose from "endless" or "display the number of time value exceeds"
(while pressing the XXX key, top 2digits will be displayed)
Output timing
Reset Input
Option : Type L1
Option : Type L2
Sensor input respond
Option : Type HI
Sensor
Input
Number of decimal setting
overscale Display
Display Range
Input signal
Option : Type F
Option : Type V3
Option : Type N
Sensor power supply
Option : Type S24
P4