SHIMPO DT-601CG User Manual
Page 18

10. INITIAL VALUE AND INITIALIZATION
If the special request was made prior to shipment, initial value is set as required.
Without the request, initial value is set as below.
Set value for each mode
A
B
C
D
E
F
0
0.
0
0
0
0
0
1.
1
0
0
0
0
2.
3
0
0
0
0
3.
1
0
0
0
0
4.
3
0
0
1
0
5.
0
-
-
0
-
-
0
6.
0
0
-
0
-
0
7.
1
3
1
3
0
8.
0
-
0
0
-
0
9.
-
0
1
4
-
1
0.
0
0
0
0
1
1.
1
0
0
0
1
2.
0
-
0
0
-
1
3.
0
-
0
1
-
Each preset value
9
9
9
9
9
9
9
9
9
9
9
9
Display offset value
0
0
0
0
0
0
0
0
0
0
0
0
Mode protect setting value
Initialization
Initialization can be done by turning the power on while pressing ENT key.
After the initialization, set value will be as chart 2, 3, 4 and 5.
calculation holding data and batch count data will be set as ZERO.
Caution
Initialization makes every current set value to be reset. Record the current value prior to the initialization.
* If the internal computer has interference due to some external factors such as noise,
follow the above steps and do the initialization, then set the value as required.
Mode protect
setting value
L - OFF
OFFSET 2
initial value
memo
initial value
memo
OFFSET 1
PRESET A
PRESET B
Mode #
initial value
memo
initial value
memo
P16