12. SETTING OF PRESET VALUE
Do the following operation for setting of the preset value of each alarm output.
Setting range is "-99999 - 999999.
Preset B's setting range is "0000.0 - 00099.9" when output is 1 stage and secondary output.
Decimal point synchronizes with setting of the "Mode00"(ref.P19).
Initial value is "999999"
Refer to "Mode05","Mode06","Mode07"(from P25 up) for setting of the alarm output action(OUT1&3, OUT2&4).
Caution
1. Do not turn off the power while registering the set value
(from pressing ENT until return to measurment display)
2. Mode Protect does not function.
3. Reset it before starting measurement when PRESET Value is changed.
Display
Operation
Operation Key
Press Mode key more than 2 seconds.
OUT1&3's LED light, then PRESET of OUT1&3 is
called.
PRESET Value is switched pushing Mode Key.
Also, The indicator-A displays "-".
Change to right the position of flashing digit.
One hit makes 1digit move right hand side.
Change the value of flashing digit.
One hit makes the value bigger/smaller by 1.
Register the set value. After finishing the
setting,register setting with this key. After
registration, measurment display will appear.
Return to measurement display without registering
the set value.