beautypg.com

SHIMPO DT-601CG User Manual

Page 33

background image

Mode#

Setting of blank display, external input function, and overscale display

0 8

A

B

C

D

E

F

0

8.

0

0

0

Overscale display

0 : 3rounds stop
1 : Endless
2 : Up key to show numbers of time go over (upper 2digits)

External input function

0 : Banned input
1 : Hold input
2 : Lap count input
3 : Display switch input

Blank display

0 : No Blank display (Display measured value)
1 : Blank display (No Display measured value)

[Blank display]

Set whether to display measured value or not. Only the measured value will blink when
"blank display" is set.
Alarm output LED and hold LED will functuon normally.

[External input function]

Setting the function of terminal block 2 to 3. When it is ON, hold LED will blink.

0 : Banned input -

Bann the sensor input while ON

1 : Hold input -

Keep displaying the current value while ON (blink when it functions)
measurement is proceeding internally
(overscale LED will be kept as well)

2 : Lap count input -

Once it is ON, current value will be kept and blinking.
Measurement is reset and start measureing again.
Another ON will display the value calculated internally.

3 : Switch display input - Display 1 and Display 2 are switched at every ON.

P31