SHIMPO DT-601CG User Manual
Page 30
![background image](/manuals/370348/30/background.png)
Mode#
Alarm output: Setting of alarm output 2 (OUT 1-4)
0 6
A
B
C
D
E
F
0
6.
0
0
0
Re-output selection
0: Without re-output
1: With re-output
This selection will be invalid when following mode is selected;
With automatic reset, batch count action,
puls 1 stage and secondary action
Automatic reset selection
0= without automatic reset
1= with automatic reset
This selection will be invalid when following mode is selected;
±each 1 stage preset action and batch count action
UP/DOWN selection
0: Up
1: Down
This selection will be invalid when ±each 1 stage preset action
is selected.
[UP/DOWN selection]
UP- Alarm will ba activated when Display value
≥
Preset value (upper limit output action)
DOWN- Alarm will be activated when Display value
≤
Preset value (lower limit output action)
* Display offset value and preset value should be included in setting condition when
setting is tobe changed.
[Automatic reset selection]
Without automatic reset- display value will not go back to display offset value when the output
conditions are met.
With automatic reset- dusplay value will go back to display offset value when the output
conditions are met.
Actions of each preset are as follows;
(1) Plus side 2stages preset action
UP: reset - Preset B
≥
display value - display value = display offset value - recount
DOWN: reset - Preset B
≤
display value - display value = display offset value - recount
(2) Batch count action
UP: reset - display value = display offset value - Preset A
≥
display value -
display value = display offset value - batch count display plus 1 - recount
DOWN: reset - display value = display offset value - Preset A
≤
display value -
display value = display offset value - batch count display plus 1 - recount
(3) Plus side 1stages secondary output action
UP: reset - Preset A
≥
display value - display value = display offset value - recount
DOWN: reset - Preset A
≤
display value - display value = display offset value - recount
Output mode is going to be 1 shot output when plus side 2 stages preset action or plus 1 stage
and secondary output action is selected and add automatic reset function.