beautypg.com

SHIMPO DT-601CG User Manual

Page 27

background image

Mode#

Alarm output: Setting of alarm output 1 (OUT 1-4)

0 5

* Model with optional line receiver input(L1,L2) cannot output as output terminal will be input

terminal

A

B

C

D

E

F

0

5.

0

0

Selection of preset action

0 : plus side 2 stages preset action
1 : ±each stage preset action
2 : batch count action (only the setting with automatic reset)
3 : plus 1 stage and secondary output action

(only the setting without re-output)

Display selection

0 : Display 1
1 : Display 2

Do not select display 2 when selecting A or -A with Mode 00 [measurement calculation method]

[Display selection]

Display 1 : Output against Display 1
Display 2 : Output against Display 2

[Preset action selection]

setting of output action
For the timing chart and setting condition,
refer to [output timing for preset action and setting condition]

* when changing setting, do so as display offset value

and preset value will be included in setting condition.


When Mode 05 to 07 are changed, DO NOT FORGET TO RESET BEFORE STARTING MEASURING.