By pressing the new button, a new step with its associated variable settings can be entered:

Date/ time

Set the date and time to start this step

ID/ value

For each ID item, drag and drop a variable in the list and give it the

desired value

Check times

As an FAT normally does not start at a fixed time or date, it is possible

to ignore checking of the a time element. In this case only the seconds

are checked.

Resume normal operation

Define if normal operation should start when the step starts, so if

needed this will normally be at the last step.

Please note that in this case the FAT check uses the flow offset to simulate a flow without the

need for hardware pulses.

Other functions are:

Create a new step

Press the new button

Edit a step

Select a step and press the edit button

Delete a step

Select a step and press the delete button

Create an ID/ value

Drag and drop a variable from the ID list

Edit an ID/ value

Double click on the ID

Delete an ID/ value

Select an ID and press the delete key

9 .9 Security configuration

Liquid

Gas

Steam

The SUMMIT 8800 can have 3 security modes:

Open

Any changes can be made including download of a new application

Partial

The existing application can be uploaded, changed and downloaded again.

Full

Connection is possible and applications can be uploaded, but cannot be downloaded.

Although an application can be changed in partial mode, there are still security measures to

restrict access. First of all, the user be authorized to use the configurator and secondly an ap-

plication itself can restrict the access to its menu: