GENERAL INFORMATION

09

9 .3 Translation

Liquid

Gas

Steam

English is the default language for the Summit, but it is possible to define a new language.

9 .4 Audit log

Liquid

Gas

Steam

For diagnostic purposes, the user can extend the audit trail with alarms and with up to 10 ad-

ditional data items per event. These data will be stored on an external SD card only.

9 .5 Settings

Liquid

Gas

Steam

General calculation settings are used to set the cycle time (how often all measurement and cal-

culations must be done per second), the maximum counter value and what to do with negative

station flow:.:

Figure 209 General settings

Calculation time

The cycle time or the time after which the Summit will start again

with all calculations. This number should be larger than the current

calculation duration. At the maximum, the Summit will do 4 full

cycles per second.

Counter rollover limit

The maximum counter value after which the counter restarts from

zero.

Allow negative station counters