beautypg.com

8 .2 .3 basic ethernet settings – KROHNE Summit 8800 Vol 3 User Manual

Page 122

background image

122

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol3 R02 en

SUMMIT 8800

COMMUNICATION

08

8 .2 .2 Basic RS 232/485 serial port settings

When selecting the serial ports, the user is presented from the drop down a list of options for

various types of communication:

Figure 167 Serial port type selection and a typical setting

For RS232/485 links the following settings are always required:

Baud rate

The speed of transmission in bits per second between 300 and 38400.

Parity

A check on correct transmission: none, odd, even, space or mark.

Stop bits

Gap between two transmitted words, 1 or 2 stop bits

Mode

RS232 or RS 485

Word size

Size of 1 word: 7 or 8 bits

It is essential to match these settings with the settings of the devices communicating with, oth-

erwise garbled information will be transferred.

8 .2 .3 Basic Ethernet settings

To establish communication to the SUMMIT 8800 over Ethernet, the basic settings under the

general section is always needed:

Figure 168 Ethernet configuration page