8 .3 .5 provers – KROHNE Summit 8800 Vol 3 User Manual

Page 127

background image

127

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol3 R02 en

SUMMIT 8800

COMMUNICATION

08

Timeout

Time to stop connectivity attempts between the devices

Retries

Number of attempts to establish communication before an alarm is given

Stream

Select the stream where the transmitter is installed ( for single device only)

Modbus ID 1..5

Unique Modbus identifiers for the 5 meter streams (only one for single

device)

The actual meters are selected in the stream meter input section (see volume 2):

Figure 173 Modbus master, selection of gas coriolis meter

Each meter has their own set of parameters, so please check the meter for details.

8 .3 .5 Provers

A prover and the streams to be proved may be combined in one Summit. However a prover and

the streams to be proved may also be in separate Summits. In the last case a Modbus link is

needed to connect the prover computer to the stream flow computers. The prover computer will

be master, the stream flow computers will be slaves. See volume 2.

To create the Modbus master, select one of the (gas) prover versions: