beautypg.com

Peak search track on off, 7ghz spectrum analyzer operation manual ⎯ ⎯ 56 – GW Instek GSP-827 User Manual User Manual

Page 57

background image

2.7GHz Spectrum Analyzer Operation Manual

56

Track ON

Track function will dynamically track the Peak signal and move the signal to the center. In fact, it
equal to the combination of Peak Search + Marker to Center which is performed all the time.

Note:

Because the marker continuously keeps searching the peak signal and moving it to the

center on the display, therefore the Center Frequency is changeable as long as the track
function is on.

1

Peak Search

Track

ON OFF

Start:99.5MHz

RBW:30 kHz

Stop:100.5MHz

VBW:100 kHz

Center:100.0MHz
Span:1.0MHz

Sweep:100.0ms

Step:1MHz

Ref

Lvl: -30.0 dBm

-30.0

-40.0

-50.0

-60.0

-70.0

-80.0

-90.0

-110.0

-100.0

SAT JAN 28, 2003

14:30:25

INT:REF

AMPL CAL

Marker Level Freq(MHz)

To

Peak

Peak

Left

Mkr-

>Cente

r

Peak

Right

Next

Peak

Track

ON OFF