beautypg.com

GW Instek GSP-827 User Manual User Manual

Page 18

background image

2.7GHz Spectrum Analyzer Operation Manual

17

6.2.7 Delta-Marker operation

Function key

Description

Marker

Select the Marker relative functions.

F1

Select the active marker by keying in marker number. 0

means marker 10.

1

Key in 1 to take marker 1 as example.

F2

ON/OFF>

Set Marker 1 ON.

N, … , MHz

Set frequency of marker 1.

F1

Select the second marker, marker 2 here for example.

2

Key in 2 to take marker 2 as example.

F2

ON/OFF>

Set Marker 2 ON.

N, … , MHz

Set frequency of marker 2.

F3

Δ

Mkr>

Set Marker2 as Δ marker.

1

Select the Reference Marker due to Mkr2. Key in 1 to take

marker 1 as reference marker.

Note: The table will show the level and frequency in delta reading. In this example, the

marker table will show as follows.

Marker Level Freq(MHz)

1 l1 f1

3

Δ

1

Δ

l13

Δ

f13

Which means marker 3 is the ΔMkr due to Mkr1.

6.2.8 Peak Hold, Average and Freeze the measurement

Function key

Description

Trace

Select the trace relative functions.

F3

Switch the peak hold function ON/OFF.

F4

Switch the Average function ON/OFF. When it is ON, key

in the average times.

F5

Switch the freeze function ON/OFF.

6.2.9 ACPR Measurement

Function key

Description

Pwr Measure

Select the power measurement relative functions.

F4

Setup the Power Measurement parameters.

F1

Define the channel bandwidth.

F2

Define the channel space.

F4

OFFSET>

Define the adjacent channel parameters.