Step 1 step 2 step 3, Step 6, Step 4 step 5 – Edwards Signaling 2400 Series User Manual
Page 77: Ab b b b

POWER
POWER
POWER
ZONE
DISABLED
ZONE
DISABLED
ZONE
DISABLED
ALARM
SILENCED
ALARM
SILENCED
ALARM
SILENCED
ALARM
ALARM
ALARM
GROUND
FAULT
GROUND
FAULT
GROUND
FAULT
SYSTEM
TROUBLE
SYSTEM
TROUBLE
SYSTEM
TROUBLE
CIRCUIT 1
CIRCUIT 1
CIRCUIT 1
CIRCUIT 2
CIRCUIT 2
CIRCUIT 2
SIGNAL
TROUBLE
SIGNAL
TROUBLE
SIGNAL
TROUBLE
TROUBLE
SILENCE
TROUBLE
SILENCE
TROUBLE
SILENCE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ALARM
SILENCE
ALARM
SILENCE
ALARM
SILENCE
RESET
RESET
RESET
RESET
TROUBLE
SILENCE
ALARM
SILENCE
ALARM
SILENCE
TROUBLE
SILENCE
RESET
RESET
RESET
RESET
RESET
PGM
MODE
OFF
ON
STEP 1
STEP 2
STEP 3
POWER
POWER
POWER
MODULE
A
A
A
A
A
A
A
B
B
B
B
B
C
B
B
B
C
B
C
C
C
C
C
C
D
D
D
D
D
D
E
E
E
E
E
E
SET PROGRAM MODE SWITCH TO ON.
TROUBLE SIGNAL BEEPS.
POWER LED DISPLAYS 2 PHASE FLASH (CONFIGURE IDCs).
POWER LED DISPLAYS 3 PHASE FLASH (CONFIGURE IACs).
SELECT IDC TYPES-
SELECT IAC TYPE. ACTIVE CIRCUIT TROUBLE LED SHOWS
TARGET CIRCUIT. ALARM SILENCED LED SHOWS CIRCUIT TYPE.
SELECT SIGNAL CIRCUITS TO BE ACTIVATED BY ZONE.
CIRCUIT TROUBLE LIGHTS WHEN SELECTED FOR ACTIVATION.
SELECT OUTPUT RATE. IAC TROUBLE LED DISPLAYS
ACTUAL OUTPUT PATTERN..
PRESS
POWER LED DISPLAYS 1-PHASE
FLASH.
ALL ZONE TROUBLE (YELLOW) LEDs
LIGHT WHEN MODULE IS RECOGNIZED
BY PANEL PROCESSOR.
PRESS
TO ADVANCE TO NEXT STEP.
PRESS
PRESS
PRESS
TO ADVANCE TO NEXT STEP.
PRESS
TO ADVANCE TO NEXT STEP.
TO PROGRAM THE NEXT IDC ZONE
AND REPEAT STEPS AND
FOR EACH ZONE.
TO PROGRAM NEXT IAC ZONE. REPEAT STEPS
AND FOR SECOND IAC.
TROUBLE
TROUBLE
TROUBLE
X 2
X 1
X 3
ALARM, NON-VERIFIED
SILENCEABLE
ALARM, VERIFIED DETECTOR ONLY
SUPERVISORY, N.O. DEVICES
WATERFLOW/SUPERVISORY
WATERFLOW/SUPERVISORY W/ RETARD
SIGNAL CIRCUIT 1
STEADY AMBER
STEADY AMBER
BOTH ON STEADY
CONTINUOUS
SIGNAL CIRCUIT 2
120 PULSES PER MINUTE
BOTH CIRCUITS
TEMPORAL (3-3-3)
CALIFORNIA CONTINUOUS (10 SECS. ON, 5 SECS. OFF)
CALIFORNIA MARCH TIME (10 SECS.@120SPM 5 SECS. OFF)
ALARM, VERIFIED DETECTOR & DRY
CONTACT ALARM INITIATING DEVICE
NON-SILENCEABLE
STEADY RED
STEADY GREEN
STEADY AMBER
RED
RED
OFF
AMBER
GREEN
POWER
POWER
POWER
ZONE
DISABLED
ZONE
DISABLED
ZONE
DISABLED
ALARM
SILENCED
ALARM
SILENCED
ALARM
SILENCED
ALARM
ALARM
ALARM
GROUND
FAULT
GROUND
FAULT
GROUND
FAULT
SYSTEM
TROUBLE
SYSTEM
TROUBLE
SYSTEM
TROUBLE
CIRCUIT 1
CIRCUIT 1
CIRCUIT 1
CIRCUIT 2
CIRCUIT 2
CIRCUIT 2
SIGNAL
TROUBLE
SIGNAL
TROUBLE
SIGNAL
TROUBLE
TROUBLE
SILENCE
TROUBLE
SILENCE
TROUBLE
SILENCE
TROUBLE
SILENCE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ENABLE
DISABLE
ALARM
SILENCE
ALARM
SILENCE
ALARM
SILENCE
RESET
RESET
RESET
RESET
TROUBLE
SILENCE
ALARM
SILENCE
ALARM
SILENCE
RESET
RESET
PGM
MODE
OFF
ON
STEP 6
PROGRAMMING NOTE
STEP 4
STEP 5
POWER
POWER
POWER
SET PROGRAM SWITCH TO OFF.
TROUBLE SIGNAL STOPS BEEPING.
POWER LED DISPLAYS 4- PHASE FLASH (CONFIGURE TIMERS).
POWER LED DISPLAYS 5- PHASE FLASH (CONFIGURE
AUXILIARY POWER).
SELECT ALARM SILENCE INHIBIT TIMER. ZONE DISABLED LED
INDICATES TIMER SETTING.
ALARM SILENCED LED SHOWS AUXILIARY POWER
RESET STATUS.
SELECT AUTOMATIC ALARM SILENCE TIMER. ALARM
SILENCED LED INDICATES TIMER SETTING.
PRESS
TO ADVANCE TO FINAL STEP.
POWER LED IS ON STEADY.
PRESS
TO ADVANCE TO NEXT STEP.
TROUBLE
TROUBLE
X 4
X 5
NONE
NONE
CONTINUOUS POWER
2 MINUTE
20 MINUTES
3 MINUTE
30 MINUTES
1 MINUTE
10 MINUTES
INTERRUPT ON RESET
OFF
OFF
OFF
[ALZPRG3.CDR]
A
B
A
A
A
A
B
B
B
B
C
C
C
C
D
D
PROGRAMMING TEMPLATE ON
REVERSE SIDE OF FRONT PANEL INSERT
+
PRESSING
AT ANY TIME, YOU MAY RESTORE THE FACTORY
DEFAULT SETTINGS AND RETURN TO STEP 1 BY
.