Emo‐3000 – AW Gear Meters EMO-3000 User Manual
Page 36

EMO‐3000
Operation and Programming Manual
35
USED IN:
All modes.
RELATED VARIABLES:
Engineering units for Total.
HEX ADDRESS:
0018 HEX ‐‐‐‐‐‐> same address used in EMO‐2000
BYTES:
4 Bytes DEFAULT: xxx
ASC form:
COMMAND:
reading = 101; writing = 501; E is engineering units; E is in selected
engineering units with units attached. N is normalized units in pulses.
Grand totalizer for A
This is the grand total of the channel A. The grand total is a product of adding total_A and grand total.
When the intermediate totalizer is zeroed (keyboard or hardware), the EMO‐3000 adds total_A to the
grand total. Therefore, we can view the total_A as the “job” total.
USED IN:
All modes.
RELATED VARIABLES:
Engineering units for Total.
HEX ADDRESS:
0018 HEX and 00F8 HEX, new for the EMO‐3000.
BYTES:
4 Bytes DEFAULT: xxx
ASC form COMMAND:
reading = 129; writing = 529; E is engineering units; E is in selected
engineering units with units attached. N is normalized units in Hertz
down to 1/100
th
.
Active set value for PID
The active set value selected is either the value calculated by taking the 0 ‐ 20 milli Amps in with the milli
Amps scaler or the digital PID set‐value. The milliamps input is the overriding set value. The judgment
whether mA’s are active is based on the milli Amps in offset.
USED IN:
PID mode.
RELATED VARIABLES:
Digital set value/mA’s in and mA scaler/mA’s in offset
HEX ADDRESS:
0043 HEX ‐‐‐‐> same address used in EMO‐2000
BYTES:
4 Bytes DEFAULT: xxx
ASC form
COMMAND:
reading = 102; writing = 502; E is engineering units; E is in selected
engineering units with units attached. N is normalized units in Hertz