Emo‐3000 – AW Gear Meters EMO-3000 User Manual
Page 32

EMO‐3000
Operation and Programming Manual
31
Use F2 to step up output one mA, F3 to step down. The resulting flow rate for each value displays in
engineering units. To observe ripple on the flowrate, use the F4 key. The RIPPLE function (F4) displays
the peak‐to‐peak ripple in engineering units for the duration of time that you hold in the F4 key.
1 = ACTION RATIO
If you select 1 = Action Ratio, from the Main Menu, the screen shows the Rates, Totals for inputs A and
B, and the Ratio A/B for all 12 channels.
CHA
RATE A
RATE B
RATIO
01
XXXX.X
XXXX.X
XXX.XX
02
XXXX.X
XXXX.X
XXX.XX
03
XXXX.X
XXXX.X
XXX.XX
04
XXXX.X
XXXX.X
XXX.XX
05
XXXX.X
XXXX.X
XXX.XX
06
XXXX.X
XXXX.X
XXX.XX
F1=ESC
F2=CH‐SWAP
F3=DI+
F4 = RES
F1 = ESC – returns you to the Main Menu
F2 = CH‐SWAP – shows the next six channels (7‐12)
F3 = DI+ – calls up the Job Totals screen
F4 = RES – inactive for Rate screen
CHA
JOB TOTAL ‐ A
JOB TOTAL ‐ B
‐‐RATIO
01
XXXXX.
XXXXX.
XXX.XX
02
XXXXX.
XXXXX.
XXX.XX
03
XXXXX.
XXXXX.
XXX.XX
04
XXXXX.
XXXXX.
XXX.XX
05
XXXXX.
XXXXX.
XXX.XX
06
XXXXX.
XXXXX.
XXX.XX
F1=ESC
F2=CH‐SWAP
F3=DI+
F4 = RES
F1 = ESC – returns you to the Main Menu
F2 = CH‐SWAP – shows the next six channels (7‐12)
F3 = DI+ – calls up the RATES screen
F4 = RES – resets the Job Totals; the Ratio resets accordingly