Programming with the dm‐3000, Emo‐3000 – AW Gear Meters EMO-3000 User Manual
Page 24

EMO‐3000
Operation and Programming Manual
23
F3 = RATIO DISPLAY
Use F3 on the Main Menu to select the Ratio Display Screen. This operation screen shows both the rates
from frequency inputs A and B, and the Ratio A/B.
RATIO DISPLAY
FOR CHANNEL XX
RATE A=
XXX.X ccm
RATE B=
XXX.X ccm
RATIO A/B=
XXX.XX
SET RATIO=
XX.XX
F1=ESC
F2=CHNL UP
F3=CHNL DN
F2 pages UP through the channels.
F3 pages DOWN through the channels.
To show multiple channel displays of ratio, refer to the ACTION RATIO section from the MAIN MENU.
Programming with the DM‐3000
F4 = PROGRAMMING
Selecting Programming from the Main Menu calls up the screen below.
******** PROGRAMMING MENU *****************
F1= MAIN MENU (ESC)
F2= GENERAL A
F3= PID VARIABLES
F4= GENERAL B
F5= ANALOG VARIAB.
F6= LIMIT VAR.
1= LIMIT RULES
2= RATIOS
3= LINEARIZER
4= SPECIAL REPEAT
CHANNEL CURRENTLY SELECTED IS XX
select one of the above ...................
In the following sections, you will find instructions about the above areas so you can access and
program the desired variable. However, this part of the manual does describe the effect of each variable
in the EMO‐3000 system. See pages 34 through 45 for detailed information in that regard. You will most
likely develop a general knowledge of the EMO‐3000 from the various programming screens in the DM‐
3000.