8 appendix, Appendix, Specifications – LumaSense Technologies BoilerSpection-SD User Manual
Page 85
BoilerSpection HD/SD Manual
Appendix 85
8 Appendix
Specifications
Infrared Imaging Camera and Lens
Resolution
320 x 240 pixels
Wavelength
3.9 µm
Detector
Type
Uncooled
focal
plane
array
Measurement
Range
HD: 400°C to 1600°C (752°F to 2,912°F)
SD: 500°C to 1600°C (932°F to 2,912°F)
Lens Diameter
HD: Outer diameter of lens system is 3.39” (86 mm)
SD: Outer diameter of lens system is 1.65” (42 mm)
Optical Field of
View
46° horizontal by 36° vertical
Protective Hardware
Camera Housing
HD: IP54 with vortex air cooling
SD: IP66 with vortex air cooling
Borescope Lens
Housing
HD: 304SS - Stainless steel shroud with integral air cooling and purge
SD: 310SS - Stainless steel shroud with integral air cooling and purge
Auto Retract Device
Fully automated system retracts camera in the event of power failure or loss of air
supply
Field Switch
Enclosure
IP67 / NEMA 4X (see drawings in Chapter 7)
Communications
Camera
IP addressable over Ethernet
Software and Computer
Computer
Requirements vary based on monitoring needs. Exact computer specifications will be
provided with your sales documentation.
Software
See separate software manual for details and see section 2.3.7 in this manual for an
overview.