beautypg.com

8 appendix, Appendix, Specifications – LumaSense Technologies BoilerSpection-SD User Manual

Page 85

background image

BoilerSpection HD/SD Manual

Appendix 85

8 Appendix

Specifications

Infrared Imaging Camera and Lens

Resolution

320 x 240 pixels

Wavelength

3.9 µm

Detector

Type

Uncooled

focal

plane

array

Measurement

Range

HD: 400°C to 1600°C (752°F to 2,912°F)

SD: 500°C to 1600°C (932°F to 2,912°F)

Lens Diameter

HD: Outer diameter of lens system is 3.39” (86 mm)

SD: Outer diameter of lens system is 1.65” (42 mm)

Optical Field of

View

46° horizontal by 36° vertical

Protective Hardware

Camera Housing

HD: IP54 with vortex air cooling

SD: IP66 with vortex air cooling

Borescope Lens

Housing

HD: 304SS - Stainless steel shroud with integral air cooling and purge

SD: 310SS - Stainless steel shroud with integral air cooling and purge

Auto Retract Device

Fully automated system retracts camera in the event of power failure or loss of air

supply

Field Switch

Enclosure

IP67 / NEMA 4X (see drawings in Chapter 7)

Communications

Camera

IP addressable over Ethernet

Software and Computer

Computer

Requirements vary based on monitoring needs. Exact computer specifications will be

provided with your sales documentation.

Software

See separate software manual for details and see section 2.3.7 in this manual for an

overview.