BoilerSpection HD/SD Manual

Troubleshooting 41

5.4 Retraction/Filtration

Symptom

Probable Cause

Corrective Action

Immediate retraction

Loss of air, air pressure caused by site
supply failure

Check supply of air and power

Failure to retract

Mechanical failure of the retraction
system

Check mechanical fittings and
enclosure for loose or out of
place components and repair

Lens failure due to heat.
Melts within boiler

Replace or service lens

Damage to camera/lens

Poorly tuned retraction forces
damaged to the system

Service broken components or
properly tune retraction

system to avoid future damage

Loss of air pressure

Clogged filter caused filter failure
within the filtration unit

Replace Air filters

Failure of Vortex
Cooling

Premature failure of

filtering

Excessive heat to the filter system

caused by the environment

Consider adding shielding to

reduce the air filters
environmental exposure

Auto retracts, loss of
image

Site power failure

Verify and replace failed
component

Short Circuits, loss of
image

Water damage

Verify and replace failed
component

5.5 Field Enclosures

Symptom

Probable Cause

Corrective Action

Loss of image

Communication failures ie. Ethernet
failure, connections/switch failure

Open circuit breakers and
check all power wiring
connetions

Power failure to cabinet

Check integrity of input power

supply

Communication failure due to
mechanical vibrations

Check mechanical fittings and
enclosure for loose or out of
place components and repair

Cabinet left open causing
heat/water/dust in affect components

Verify and replace failed
component

Power surges

Site supply issues causing circuit
breakers to trip

Check integrity of input power
supply