BoilerSpection HD/SD Manual

Troubleshooting 39

5 Troubleshooting

5.1 Lens

Symptom

Probable Cause

Corrective Action

Poor image – miss slag

buildup

Lens surface contamination due to

dust/dirt in the boiler environment

Air purge needed

Lens surface contamination during
installation/maintenance

Clean lens

Image offset caused by excessive heat

Air cooling needed

Focus change caused by excessive heat

Focus change caused by mechanical
vibration

Perform vibration analysis

Excessive heat causes lens component
to become opaque

Contact LumaSense (refer to
section 1.7)

Loss of image

Filters cracked because of thermal

cycling

Contact LumaSense (refer to

section 1.7)

Nose tip damaged because of excessive
heat

Contact LumaSense (refer to
section 1.7)

Damage to mechanical/internal
fixtures caused by excessive heat

Nose tip damage because of vibration
failure

Contact LumaSense (refer to
section 1.7)

Cooling shroud damaged caused by

missalignment

Contact LumaSense (refer to

section 1.7)

5.2 Camera

Symptom

Probable Cause

Corrective Action

Complete Power Failure Vibrations/internal failures

Perform vibration analysis

Loose power connections

Open circuit breakers and
check all power wiring
connections

Excessive heating

Air cooling needed or add

heat shields if hot air or
radiation from the furnace is
directly heating the failed
component or enclosure

Power surge