beautypg.com

4 maintenance, 1 recommended boilerspection maintenance schedule, 1 inspection and test – LumaSense Technologies BoilerSpection-SD User Manual

Page 35: Maintenance, Recommended boilerspection maintenance schedule, Inspection and test

background image

BoilerSpection HD/SD Manual

Maintenance 35

4 Maintenance

The BoilerSpection™ system is designed to operate continuously in harsh environments, but filter
replacement and other maintenance measures need to be implemented as described in this section

to avoid preventable wear or damage to the system.

4.1 Recommended BoilerSpection Maintenance Schedule

4.1.1 Inspection and Test

Item Description

Tools or Parts
Required

Maintenance Interval

1

Check internal camera
temperatures and diagnostics

Reported by the
system software

Weekly

2

Check

all

cooling

systems

Monthly

3

Test retraction device
performance and air settings

Monthly

4

Check connections and
control box electronics

Quarterly

5

Check air filter drains

Small

screwdriver

Weekly

6

Check air filters

Check monthly, replace
annually or sooner as required

(see below)

7

Document:

Document test and

inspection results.

Report includes comparison

to results from previous
service visits if that
information is available.

Report any noteworthy

trends/observations and
suggestions.

This manual is related to the following products: