5 making the connections, 1 air connections, Making the connections – LumaSense Technologies BoilerSpection-SD User Manual
Page 28: Air connections
BoilerSpection HD/SD Manual
BoilerSpection Installation Guide 28
3.5 Making the Connections
In order for the BoilerSpection system to operate correctly, the supplied hardware must be properly
attached to the computer and power supplied to the various parts of the system.
3.5.1 Air Connections
All hoses are provided with the BoilerSpection system and run from the air filtration system to the
camera and the retract device. The hoses are braided stainless steel and the standard length is
15 foot (4.5m).
The five air connections are as follows:
Wall box purge: This hose is typically only used on positive pressure furnaces and the steel
braided hose connects to a 1-inch NPT fitting on top of the wall box sleeve.
Retraction cylinder pressure line to insert lens: A green color-coded Quick Connect cable.
Retraction cylinder pressure line to retract lens: A red color-coded Quick Connect cable.
Lens cooling and purge air: A ¾-inch hose from the Air Filtration system regulator to quick
disconnect.
Camera enclosure cooling line: A ½-inch hose from the Air Filtration system regulator to
quick disconnect fitting.
Connect the flexible air hoses to the camera and retract device assembly.
Figure 20: HD Camera System Air Line Connections
Wall Box Purge
Lens Cooling and Purge
Camera Pressure Line
Retract Camera
Pressure Line
Camera Enclosure
Cooling