Brocade Fabric Watch Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 111

215 G HEALTHY 000:00 - - - - - - - - - - - - -
216 VE HEALTHY 061:19 - - - - - - - - - - - - -
217 VE HEALTHY 061:19 - - - - - - - - - - - - -
(output truncated)
NOTE
Output of the Port Detail report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than the port number is
displayed for that port; for example: 000 ----------------Not a member of current
Admin Domain-------------------.
The table below lists and describes each item in the Port Detail report.
Port Detail report columns
TABLE 33
Report item Description
LFA
Link Loss: The number of link loss occurrences out of range for a specified time period.
LSY
Sync Loss: The number of sync loss occurrences out of range for a specified time period.
LSI
Signal Loss: The number of signal loss occurrences out of range for a specified time period.
PER
Protocol Error: The number of protocol errors out of range for a specified time period.
INW
Invalid Word: The number of invalid words out of range for a specified time period.
CRC
Invalid CRC: The number of CRC errors out of range for a specified time period.
PSC
Port hardware state changed too often because of fabric reconfiguration.
BLP
Buffer limited port: The switch status changes when a port is in a buffer limited mode based on
the switch status policy.
STM
SFP temperature is out of specifications.
SRX
SFP receive power is out of specifications.
STX
SFP transmit power is out of specifications.
SCU
SFP current is out of specifications.
SVO
SFP voltage is out of specifications.
Fabric Watch Reports
Fabric Watch Administrators Guide
111
53-1003142-01