Configuring alarms for frus using web tools – Brocade Fabric Watch Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 103

1. Open the Fabric Watch window.
2. In the Fabric Watch Explorer pane, select a class.
You can set alarms for information on a switch only if that information is monitored by Fabric Watch
for that switch; not all alarm options are available for all switches.
3. Select the Threshold Configuration tab.
4. Under Area Selection, select the area with the alarms that you want to enable or disable.
5. Select the Element Configuration subtab.
6. Select an element from the Element Selection menu.
7. In the Status area, choose one of the following:
• To disable threshold alarms, click Disabled and click Apply. The threshold alarms are disabled
and you do not need to continue with this procedure.
• To enable threshold alarms, click Enabled and continue with the next step.
8. Select the Triggered behavior type to receive threshold alarms only when they are triggered by
events that you defined.
9. Select a time interval in which to receive the threshold alarms from the Time Interval menu.
10.Click Apply.
11.You can apply the selections on this panel to multiple elements simultaneously by performing the
following steps.
a)
Click Apply More. The Multiple Selection dialog box displays.
b)
Select the check boxes next to the indices of all applicable elements and click OK.
Configuring alarms for FRUs using Web Tools
Configuration for the FRU class is different from configuration for the other classes. Because FRUs are
not monitored through a threshold-based system, they have a simpler interface for configuration.
For FRUs, you configure the states for which an event occurs, using the following procedure.
1. Open the Fabric Watch window.
2. Select the Threshold Configuration tab.
3. In the Fabric Watch Explorer pane, select a FRU class.
4. Under Area Selection, select a FRU type from the list.
5. Select the alarm states for which you want an event to register.
If a FRU of the selected type is determined that it is one of the selected states, an event will occur.
6. Select the methods by which you want to be notified about the FRU alarms.
For FRUs, the only options are error log and e-mail alert.
7. Click Apply to apply the changes to the switch.
A confirmation dialog box displays, asking if you want to apply the changes to the switch.
8. Click OK to save the changes to the switch.
Configuring alarms for FRUs using Web Tools
Fabric Watch Administrators Guide
103
53-1003142-01