16 attributes of message list components, Attributes of message list components -33, App index – Yokogawa Removable Chassis DX1000N User Manual
Page 63: Name of each component, Attribute setting dialog, List of attributes
2-33
IM 04L41B01-04E
Advanced Settings of Screen and Component
1
2
3
App
Index
2.16 Attributes of Message List Components
These components are used to display the message list.
Component type
(See Section 1.4.)
List display
Overlap restriction
(See Section 1.4.)
A
Update
cycle
1 sec
Name of Each Component
Header (quantity, title)
Message string
Message mark
Attribute Setting Dialog
(*)
* The Batch group no. will be displayed only when Multi batch (additional specification /BT2) is valid.
List of Attributes
Attribute
Description
Default value
ID
Number automatically assigned for component
identification.
80 to 83
Font
Sets the character size of the message list. You can
select either [Font 6] or [Font 8].
Font 6(DX1000)
Font 8(DX2000)
Batch group
no
only with additional
spec. /BT2
Sets the batch group
number. Selectable from among
the number of multi batches configured in the basic
setting.
The batch group number will be displayed only when
Multi batch is valid.
1
Color
Set the color of the string. Selectable from among [Red],
[Green], [Blue], [B.violet], [Brown], [Orange], [Y.green],
[Lightblue], [Violet], [Gray], [Lime], [Cyan], [Darkblue],
[Yellow], [Lightgray], [Purple], [Pink], [L.brown],
[L.green], [Darkgray], [Olive], [Darkcyan], [S.green],
[Black], [White], and [BASE].
Black
Background color
Sets the fill color of the message list area. Selectable
from among [white] and [black].
White
BG transparent
You can choose to make the background color
transparent by setting [On] or [Off].
The background transparency is valid when the trend
display component exists under the message list that
completely overlaps with it. This transparency is invalid
if the message list protrudes from the trend display
component.
Off
Header display
Sets [On] or [Off] to indicate whether or not the header
is displayed. Setting On displays this item on the
execution screen. The builder screen always hides this
item.
Off
Mark display
Sets [On] or [Off] to indicate whether or not the
message mark is displayed. Setting On displays this
item on the execution screen. The builder screen
always hides this item.
On
Continued on next page