1.11 Register Components in the GR. CTRL
It is a function that switches the display of components created by each display group.
In the Gr. Ctrl dialog, you will be able to list or edit the settings configured by attribute of
each component. This section explains the operation using the soft key menu.
You will configure the group control based on individual component’s attributes. See
Chapter 2 and
Appendix 1.
Procedure
1.
Pres the
Gr. Ctrl soft key.
2.
Press the
soft key for the Grp control number to be registered.
The Grp control dialog appears.
3.
Set the batch group number
*
, group number, and switching groups using the
soft
key.
* The batch group number is displayed when the Multi batch (additional
specifications/ BT2) is valid.
When the Multi batch /BT2 is valid
4.
Use the
right arrow key to display the second page.
5.
Enter the ID number for components to be managed as a group.
6.
Use the
arrow key to select [OK] and press DISP/ENTER.
Explanation
If components are managed as a group, you can switch channels to be displayed by
switching groups on the execution screen with the left and right arrow keys.
• You can switch the group number of components which contain the group number as
an attribute (trend and scale).
• You can switch the channel number of components which only contain the channel
attribute (channel number).
Batch group no
Setting range: From 1 to the number of Multi batches defined in the basic setting
Group no
Setting range:
If the multiple batch is Off, DX1000 is between 1 and 10 and DX2000 is between 1 and 36.