beautypg.com

List of attributes – Yokogawa Removable Chassis DX1000N User Manual

Page 40

background image

2-10

IM 04L41B01-04E

List of Attributes

Attribute

Description

Default value

ID

Number automatically assigned for component identification.

84 to 87

Batch group no

only with additional

spec. /BT2

Set the batch group number. The batch number needs to be within

the range from [1] to number of Multi batch configured at the basic

settings.

The batch group number will be displayed only when Multi batch is

valid.

1

Group no

Set the group number.
Multi batch Off
You can select a number from [1] to [10] for DX1000, [1] to [36] for

DX2000.
Multi batch On
You can select a number from [1] to [6] for DX1000, [1] to [12] for

DX2000.

1

Direction

Set the direction of trend display. You can select [SET], [Horizon], or

[Vertical].

SET

Compress ratio

Set the ratio of rendering 1 dot data.
You can select [1], [2], [4], [5], [6], [7], or [8].

1

Wave area

Set the ratio used for displaying a wave to the width of temporal axis

direction as 100%.
You can select [100], [90], [80], [70], [60], or [50].

100

Margin

Sets whether or not to display a margin on both sides in the direction

of the span.
[On]: Margin of 3% of component width is added in the direction of

the span

[Off]: The margin is not displayed

Off

Change group

Sets whether or not to switch the group display in the execution

panel when the left/right keys are pressed.
[On]: Display switched [Off]: Display not switched

On

Message mark

size

Set the size of message mark to be displayed. You can select either

[Small] or [Large]. Note that this field will not be available when

[Message display] field is set to [Off].

Large

Time/div font

Set the character size of Time/div display. You can select either [Font

6] or [Font 8]. Note that this field will not be available when Time/div

display is set to [Off].

Font 6(DX1000)
Font 8(DX2000)

Time font

Set the character size of GRID time display. You can select either

[Font 5] or [Font 6]. Note that this field will not be available when time

display is set to [Off].

Font 5

Time interval

Sets the interval for displaying the time. It cannot be set when [Time

display] is [Off].
[EveryGrid]: Displays in all time grids
[Alternate]: Displays in every other time grid

Alternate

2nd span

Sets [On] or [Off] to indicate whether the 2nd span is Valid or Invalid.

See section 2.2

Off

2nd span Lower

Enter a value between 0% for the lower limit and 90% for the upper

limit, with the difference between the 2 spans being 10% or greater.

See section 2.2

0

2nd span Upper

Enter a value between 10% for the lower limit and 100% for the

upper limit, with the difference between the 2 spans being 10% or

greater.

See section 2.2

100

Message display

You can choose to show or hide the message mark by setting [On]

or [Off].

On

Time/div display

You can choose to hide or show the Time/div display by setting [On]

or [Off].

On

Time display

Sets [On] or [Off] to indicate whether or not the grid time is displayed. On

Scale grid display

Sets [On] or [Off] to indicate whether or not the scale grid is

displayed. When [Time grid display] is [Off], the scale grid is

automatically set to [Off], and cannot be set.

On

Continued on next page

2.5 Attributes of Trend Components

This manual is related to the following products: