Prompt index, Prompt index a.13, I j k – Watlow Power Series Rev H User Manual
Page 67
A p p e n d i x
Wa t l o w P o w e r S e r i e s
■
A . 1 3
Prompt Index
A
[``Ad]
Select Analog to Digital Channel 6.19
[Addr]
Unit Address Select 6.12
[ALÇ`]
Heat Sink Alarm Temp 6.18
[aLÇ`]
Heat Sink Over Temperature Alarm
Temperature 6.10
[a|lgc]
Active Relay State 6.10
[ALgo]
Power Control Algorithm Select 6.5
[Algo]
Setup Control Algorithm Menu 6.5-
6.6
{`Alr}
Alarms Setup Menu Lockout 6.16
[`ALr]
Setup Alarms Configuration Menu 5.7,
6.10-6.11
B
[baud]
[BAuP]
[bl`U]
Baseline Voltage Read/Adjust 6.7
C
[```Ç]
Heat Sink Temperature (°C) 6.18
[CALA]
Calibrate Analog Input Request 6.21
[CALr]
[`Cf9]
Retransmit Configuration Select 6.12
{`CIn}
Analog Input Factory Menus Lockout
6.16
[CIn1] [CIn2] [CIn3] Calibrate Analog Input
Signal Zone 1, 2, or 3 Menus 6.21-6.22
[CL`A]
Current Limit Set Point (A) 5.5, 6.9
[`CLi]
Current Limit Select (On/Off) 5.5, 6.8
{COM}
Comms Setup Menu Lockout 6.16
[COM]
Setup Comms Configuration Menu
6.12
[Cnts]
Read Selected Analog to Digital
Counts 6.19
[cont]
[C|rtr]
Retransmit Cal Factory Menu Lockout
6.16
[Crtr]
Calibrate Retransmit Menu 6.22
[`Ctr]
Control Setup Menus Lockout 6.16
[Ctr1] [Ctr2] [Ctr3] Setup Control Zone 1,
[`Cur]
[Cur1], [Cur2], [Cur3] Load Current (Amps)
[Cur–]
Maximum Amps Retransmit 6.13
[Cur_]
Minimum Amps Retransmit 6.13
[C|Wd]
Comms Watchdog Alarm Configura-
tion 6.11
D
[dAtA]
System Data Factory Menu Lockout
6.17
[dATA]
System Data Manipulation Menu
6.15-6.16
[date]
[dFLt]
[dFlt]
Default Numeric Input Signal (%) 6.6
[diAg]
Diagnostics Factory Menu Lockout 6.17
[diag]
[dIsp]
Display Test 6.20
E F
[fcty]
[Fcty]
Factory Page 6.14 - 6.22
[Freq]
Frequency Out of Tolerance Alarm
Configuration 6.11
[FrEq]
Line Frequency (Hz) 6.1
[`FTB]
Fixed Time Base 5.1
[`FTB]
Fixed Time Base (Sec) 6.5
G
[glbl]
Global Alarm Configuration 5.7, 6.10
{gLOC}
H
[`HbC]
Heater Bakeout Overcurrent Trip
6.8
[`Hbo]
Heater Bakeout Select (On/Off) 5.4,
6.8
[`Hbt]
Heater Bakeout Timeout 6.2
[Hbt1] [Hbt2] [Hbt3] Heater Bakeout Time-
[HI`Ç]
Record High Heat Sink Temp 6.18
[HrS–]
[HrS_]
[`HUa]
HUA–]
Maximum kVA Retransmit 6.13
[HUA_]
Minimum kVA Retransmit 6.13
[HUa1] [HUa2] [HUa3] Load Power (kVA) 6.3,
[HUer]
Hardware Version 6.17
I J K
[ICur]
[``In]
Analog (mA or V) or Numeric (%)
Input Signal 6.1, 6.4
[``In]
Input Signal Method Select (dig, mA,
volt) 6.6
[``In]
[In`1], [In`2], [In`3] Analog (mA or V) or
Numeric (%) Input Signal 6.2, 6.3
[Indf]
Inductive Load Factor Request 6.9
[Info]
Unit Information Menu 6.17-6.18
L
[l!a1]
Line Loss Alarm, Most Recent 6.19
[l!a2] [l@a2] [l#a2] Line Loss 6.19
[l!a3] [l@a3] [l#a3] Alarm Type 6.19
[l@a1]
Line Loss Alarm, Previous 6.19
[l#a1]
Line Loss Alarm, Least Recent 6.19
[Lbal]
Load Balance Alarm Config. 6.11
[Ldif]
Load Balance Percentage 6.11
[Line]
Line Loss Alarm Config. 6.10
[LoAd]
[`LOC]
Global/Menu Lockouts Menu 6.16-6.17
[lrn|A]
Learn Input Learn Request (Hi, Lo)
6.7
[lrn|U]
Baseline Voltage Learn Request 6.7
M N
[Min]
Heater Bakeout Select Time 5.4, 6.8
[nna–]
Adjust High mA Cal Point 6.21
[nna_]
Adjust Low mA Cal Point 6.21
[nna–]
[nna_]
[nna–]
Set Analog Input High Current (mA)
6.6
[nna_]
Set Analog Input Low Current (mA)
6.6
[nUOL]
Enable NVOL Storage 6.16
O
[Open]
Heater Open Alarm Config. 6.10
[`OPt]
Config. Installed Options 6.18
{`Opt}
Options Setup Menus Lockout 6.16
[Opt1] [Opt2] [Opt3] Setup Options Zone 1,
[``OT]
Heat Sink Over Temperature Alarm
Configuration 6.10
[``OU]
Over Voltage Alarm Config. 6.11
[`Out]
Output Power (%) 6.2, 6.4
[Out1], [Out2], [Out3] Output Power (%)
P Q
[p|bAl]
Phase Balance Alarm Config. 6.11
[Phas]
Display Phase 6.4
[PhaS]
[Ph2t]
Phase Angle 5.2
[`PW]
Factory Password 6.20
[`PW]
Factory Password Entry 6.20
[PWr]
Watchdog Failure Output Power
Select (%) 6.12
R
[ratA]
Unit Current Rating (Amps) 6.18
[rATE]
Maximum Rate of Change (%/100msec)
6.8
[ratU]
Unit Voltage Rating (Volts) 6.17
[rdLY]
Reactance Delay 6.8
[reSt]
[rEtr]
Retransmit Set Test Word 6.20
{retr}
Retransmit Setup Menu Lockout 6.16
[rEtr]
Setup Retransmit Configuration Menu
6.12-6.14
[rt|C–]
Set Retransmit Output High Current
(mA) 6.13
[rt|C_]
Set Retransmit Output Low Current
(mA) 6.13
[rt|U–]
Set Retransmit Output High Voltage
(Volts) 6.14
[rt|U_]
Set Retransmit Output Low Voltage
(Volts) 6.14
S
[Sbld]
[sdÇ`]
Factory Safety Shutdown Temp 6.18
[`seC]
Watchdog Timeout (Sec) 6.12
[`Set]
Setup Page Select 6.5-6.13
[`Sn–]
Unit Serial Number High Digits 6.17
[`Sn_]
Unit Serial Number Low Digits 6.17
[Soft]
[Soft]
Soft Start Time (Sec) 6.8
[SUEr]
Software Version 6.17
T
[`tol]
Heater Tolerance Alarm Configuration
6.10
[tol–]
High Tolerance Set Point (A) 6.9
[tol_]
Low Tolerance Set Point (A) 6.9
[type]
Load Type Select 6.7
[type]
Retransmit Type Select 6.12
U V W X Y Z
[`UAL]
Read Selected Input Value 6.20
[``UC]
Line Voltage Compensation 6.6
[``UC]
Voltage Compensation Alarm
Configuration 6.11
[`UoL]
Line Potential (Volts) rms 6.2
[Uol1], [Uol2], [Uol3] Line Potential (Volts)
[Uol–]
Adjust High V Cal Point 6.21
[Uol_]
Adjust Low V Cal Point 6.21
[Uol–]
Retransmit Cal Volts High 6.22
[Uol_]
Retransmit Cal Volts Low 6.22
[Uol–]
Set Analog Input High Voltage (Volts)
6.7
[Uol_]
Set Analog Input Low Voltage (Volts)
6.6
[Urtb]
Variable Time Base 5.2
[`Wd]
[2onC]
[2one]
[2one]
Zone Display Selection 6.2, 6.3