Prompt Index

A

[``Ad]

Select Analog to Digital Channel 6.19

[Addr]

Unit Address Select 6.12

[ALÇ`]

Heat Sink Alarm Temp 6.18

[aLÇ`]

Heat Sink Over Temperature Alarm
Temperature 6.10

[a|lgc]

Active Relay State 6.10

[ALgo]

Power Control Algorithm Select 6.5

[Algo]

Setup Control Algorithm Menu 6.5-
6.6

{`Alr}

Alarms Setup Menu Lockout 6.16

[`ALr]

Setup Alarms Configuration Menu 5.7,
6.10-6.11

B

[baud]

Unit Baud Rate Select 6.12

[BAuP]

Backup Data Set 6.15

[bl`U]

Baseline Voltage Read/Adjust 6.7

C

[```Ç]

Heat Sink Temperature (°C) 6.18

[CALA]

Calibrate Analog Input Request 6.21

[CALr]

Cal Retransmit Request 6.22

[`Cf9]

Retransmit Configuration Select 6.12

{`CIn}

Analog Input Factory Menus Lockout
6.16

[CIn1] [CIn2] [CIn3] Calibrate Analog Input

Signal Zone 1, 2, or 3 Menus 6.21-6.22

[CL`A]

Current Limit Set Point (A) 5.5, 6.9

[`CLi]

Current Limit Select (On/Off) 5.5, 6.8

{COM}

Comms Setup Menu Lockout 6.16

[COM]

Setup Comms Configuration Menu
6.12

[Cnts]

Read Selected Analog to Digital
Counts 6.19

[cont]

dc contactor 5.2

[C|rtr]

Retransmit Cal Factory Menu Lockout
6.16

[Crtr]

Calibrate Retransmit Menu 6.22

[`Ctr]

Control Setup Menus Lockout 6.16

[Ctr1] [Ctr2] [Ctr3] Setup Control Zone 1,

2, and 3 Menus 6.6-6.8

[`Cur]

Load Current (Amps) rms 6.2

[Cur1], [Cur2], [Cur3] Load Current (Amps)

rms 6.3, 6.4

[Cur–]

Maximum Amps Retransmit 6.13

[Cur_]

Minimum Amps Retransmit 6.13

[C|Wd]

Comms Watchdog Alarm Configura-
tion 6.11

D

[dAtA]

System Data Factory Menu Lockout
6.17

[dATA]

System Data Manipulation Menu
6.15-6.16

[date]

Manufactured Date (yymm) 6.17

[dFLt]

Default Data Set 6.15

[dFlt]

Default Numeric Input Signal (%) 6.6

[diAg]

Diagnostics Factory Menu Lockout 6.17

[diag]

Diagnostics Menu 6.19-6.20

[dIsp]

Display Test 6.20

E F

[fcty]

Factory Mode Request 6.20

[Fcty]

Factory Page 6.14 - 6.22

[Freq]

Frequency Out of Tolerance Alarm
Configuration 6.11

[FrEq]

Line Frequency (Hz) 6.1

[`FTB]

Fixed Time Base 5.1

[`FTB]

Fixed Time Base (Sec) 6.5

G

[glbl]

Global Alarm Configuration 5.7, 6.10

{gLOC}

Global Lockout 5.6, 6.16

H

[`HbC]

Heater Bakeout Overcurrent Trip
6.8

[`Hbo]

Heater Bakeout Select (On/Off) 5.4,
6.8

[`Hbt]

Heater Bakeout Timeout 6.2

[Hbt1] [Hbt2] [Hbt3] Heater Bakeout Time-

out 6.2, 6.3

[HI`Ç]

Record High Heat Sink Temp 6.18

[HrS–]

Accum Hours (10K - 100M) 6.18

[HrS_]

Accum Hours (0 - 9999) 6.18

[`HUa]

Load Power (kVA) 6.2, 6.4

HUA–]

Maximum kVA Retransmit 6.13

[HUA_]

Minimum kVA Retransmit 6.13

[HUa1] [HUa2] [HUa3] Load Power (kVA) 6.3,

6.4

[HUer]

Hardware Version 6.17

I J K

[ICur]

Inductive Current 6.9

[``In]

Analog (mA or V) or Numeric (%)
Input Signal 6.1, 6.4

[``In]

Input Signal Method Select (dig, mA,
volt) 6.6

[``In]

Select Discrete Input 6.20

[In`1], [In`2], [In`3] Analog (mA or V) or

Numeric (%) Input Signal 6.2, 6.3

[Indf]

Inductive Load Factor Request 6.9

[Info]

Unit Information Menu 6.17-6.18

L

[l!a1]

Line Loss Alarm, Most Recent 6.19

[l!a2] [l@a2] [l#a2] Line Loss 6.19
[l!a3] [l@a3] [l#a3] Alarm Type 6.19
[l@a1]

Line Loss Alarm, Previous 6.19

[l#a1]

Line Loss Alarm, Least Recent 6.19

[Lbal]

Load Balance Alarm Config. 6.11

[Ldif]

Load Balance Percentage 6.11

[Line]

Line Loss Alarm Config. 6.10

[LoAd]

Load Activity Indicator 6.1

[`LOC]

Global/Menu Lockouts Menu 6.16-6.17

[lrn|A]

Learn Input Learn Request (Hi, Lo)
6.7

[lrn|U]

Baseline Voltage Learn Request 6.7

M N

[Min]

Heater Bakeout Select Time 5.4, 6.8

[nna–]

Adjust High mA Cal Point 6.21

[nna_]

Adjust Low mA Cal Point 6.21

[nna–]

Retransmit Cal mA High 6.22

[nna_]

Retransmit Cal mA Low 6.22

[nna–]

Set Analog Input High Current (mA)
6.6

[nna_]

Set Analog Input Low Current (mA)
6.6

[nUOL]

Enable NVOL Storage 6.16

O

[Open]

Heater Open Alarm Config. 6.10

[`OPt]

Config. Installed Options 6.18

{`Opt}

Options Setup Menus Lockout 6.16

[Opt1] [Opt2] [Opt3] Setup Options Zone 1,

2, and 3 Menus 6.8-6.9

[``OT]

Heat Sink Over Temperature Alarm
Configuration 6.10

[``OU]

Over Voltage Alarm Config. 6.11

[`Out]

Output Power (%) 6.2, 6.4

[Out1], [Out2], [Out3] Output Power (%)

6.2, 6.3

P Q

[p|bAl]

Phase Balance Alarm Config. 6.11

[Phas]

Display Phase 6.4

[PhaS]

Retransmit Phase Select 6.13

[Ph2t]

Phase Angle 5.2

[`PW]

Factory Password 6.20

[`PW]

Factory Password Entry 6.20

[PWr]

Watchdog Failure Output Power
Select (%) 6.12

R

[ratA]

Unit Current Rating (Amps) 6.18

[rATE]

Maximum Rate of Change (%/100msec)
6.8

[ratU]

Unit Voltage Rating (Volts) 6.17

[rdLY]

Reactance Delay 6.8

[reSt]

Restore Data Set 6.15

[rEtr]

Retransmit Set Test Word 6.20

{retr}

Retransmit Setup Menu Lockout 6.16

[rEtr]

Setup Retransmit Configuration Menu
6.12-6.14

[rt|C–]

Set Retransmit Output High Current
(mA) 6.13

[rt|C_]

Set Retransmit Output Low Current
(mA) 6.13

[rt|U–]

Set Retransmit Output High Voltage
(Volts) 6.14

[rt|U_]

Set Retransmit Output Low Voltage
(Volts) 6.14

S

[Sbld]

Software Build Number 6.17

[sdÇ`]

Factory Safety Shutdown Temp 6.18

[`seC]

Watchdog Timeout (Sec) 6.12

[`Set]

Setup Page Select 6.5-6.13

[`Sn–]

Unit Serial Number High Digits 6.17

[`Sn_]

Unit Serial Number Low Digits 6.17

[Soft]

Soft Start 5.3

[Soft]

Soft Start Time (Sec) 6.8

[SUEr]

Software Version 6.17

T

[`tol]

Heater Tolerance Alarm Configuration
6.10

[tol–]

High Tolerance Set Point (A) 6.9

[tol_]

Low Tolerance Set Point (A) 6.9

[type]

Load Type Select 6.7

[type]

Retransmit Type Select 6.12

U V W X Y Z

[`UAL]

Read Selected Input Value 6.20

[``UC]

Line Voltage Compensation 6.6

[``UC]

Voltage Compensation Alarm
Configuration 6.11

[`UoL]

Line Potential (Volts) rms 6.2

[Uol1], [Uol2], [Uol3] Line Potential (Volts)

rms 6.3, 6.4

[Uol–]

Adjust High V Cal Point 6.21

[Uol_]

Adjust Low V Cal Point 6.21

[Uol–]

Retransmit Cal Volts High 6.22

[Uol_]

Retransmit Cal Volts Low 6.22

[Uol–]

Set Analog Input High Voltage (Volts)
6.7

[Uol_]

Set Analog Input Low Voltage (Volts)
6.6

[Urtb]

Variable Time Base 5.2

[`Wd]

Watchdog Select (On/Off) 6.12

[2onC]

Number Zones Configured 6.18

[2one]

Retransmit Zone Select 6.13

[2one]

Zone Display Selection 6.2, 6.3