Interposed Regulator Kit Ordering Code
Ordering Components
• Manifold or Subbase Kit required.
• Interposed Regulator Kit configured
for Internal Pilot as standard.
• Order valve as External Pilot.
Internal Pilot Configuration -
Pressure in Base Port 1 feeds regulator configured for Internal Pilot which feeds valve configured for External Pilot.
External Pilot Configuration - Size 1, Size 2, Size 3
An External Pilot pressure in Port 12 or 14 of the base feeds thru the Interposed Regulator 12 or 14 galley directly to the 12/14 pilot of the valve.
This configuration takes an External Pilot from the 12 port of the base and passes it thru the regulator to feed the 12 galley of the valve.
How to Configure Interposed
Regulator / Valve Combinations
R PS5637 1 6
6 P
Basic Series
Size 00
15407-1, 18mm
PS5637
15407-2, 18mm
PS5638
Size 0
15407-1, 26mm
PS5537
15407-2, 26mm
PS5538
Regulator Function
Common Pressure Regulator
1
Independent Pressure Regulator 2
#4 Port Regulator / Gauge*
2
2-60 PSIG w/o Gauge
3
5-125 PSIG w/o Gauge
5
2-60 PSIG w/Gauge
6
5-125 PSIG w/Gauge
* For Common Pressure Regulator Option, Regulator Gauge callout
must be the same number for both Port #4 and Port #2. (Example: 166)
#2 Port Regulator / Gauge*
2
2-60 PSIG w/o Gauge
3
5-125 PSIG w/o Gauge
5
2-60 PSIG w/Gauge
6
5-125 PSIG w/Gauge
* For Common Pressure Regulator Option, Regulator Gauge callout
must be the same number for both Port #4 and Port #2. (Example: 166)
R PS4037 1 6
6 C P
Basic Series
Size 1
5599-1
PS4037
5599-2
PS4038
Size 2
5599-1
PS4137
5599-1
PS4138
Size 3
5599-1
PS4237
5599-1
PS4238
Regulator Function
Common Pressure Regulator
1
Independent Pressure Regulator 2
Selector Regulator
3
#2 Port Regulator / Gauge*
0**
Line By-Pass Plate
1
1-30 PSIG w/o Gauge
2
2-60 PSIG w/o Gauge
3
5-125 PSIG w/o Gauge
4
1-30 PSIG w/Gauge
5
2-60 PSIG w/Gauge
6
5-125 PSIG w/Gauge
C
Air Pilot w/60 PSIG Gauge
D
Air Pilot w/160 PSIG Gauge
* For Common Pressure Regulator Option, Regulator Gauge callout must
be the same number for both Port #4 and Port #2. (Example: 166)
** Pressure Line By-Pass Option can only be used with Independent and
Selector Regulators (Option 2 & 3 in Interposed Block Function).
#4 Port Regulator / Gauge*
0**
Line By-Pass Plate
1
1-30 PSIG w/o Gauge
2
2-60 PSIG w/o Gauge
3
5-125 PSIG w/o Gauge
4
1-30 PSIG w/Gauge
5
2-60 PSIG w/Gauge
6
5-125 PSIG w/Gauge
C
Air Pilot w/60 PSIG Gauge
D
Air Pilot w/160 PSIG Gauge
* For Common Pressure Regulator Option, Regulator Gauge callout must
be the same number for both Port #4 and Port #2. (Example: 166)
** Pressure Line By-Pass Option can only be used with Independent and
Selector Regulators (Option 2 & 3 in Interposed Block Function).