beautypg.com

Ross Controls 5599_I POPPET SERIES W64 User Manual

Series w64 poppet valves, Solenoid control, Iso 5599/i - drop cord connections

background image

ROSS CONTROLS

®

12

1.0
2.1
4.0

1.0
2.1
4.0

1.0
2.1
4.0

1.0
2.1
4.0

1
2
3

1
2
3

1
2
3

1
2
3

W6476B2401
W6476B3401
W6476B4401

W6476B2407
W6476B3407
W6476B4407

W6476B2402
W6476B3402
W6476B4402

W6476B2408
W6476B3408
W6476B4408

33
33
50

16
16
16

33
33
50

16
16
16

2.9
1.2
0.7

2.9
1.2
0.7

2.9
1.2
0.7

2.9
1.2
0.7

5.9
2.3
1.2

5.6
2.3
1.1

5.9
2.3
1.2

5.6
2.3
1.1

1.3 (0.6)
1.8 (0.8)
2.8 (1.3)

1.8 (0.8)
2.3 (1.1)
3.3 (1.5)

1.3 (0.6)
1.8 (0.8)
2.8 (1.3)

1.8 (0.8)
2.3 (1.1)
3.3 (1.5)

5.6 (142)
6.3 (160)
6.4 (163)

6.9 (175)
7.7 (196)
6.4 (163)

5.6 (142)
6.3 (160)
6.4 (163)

6.9 (175)
7.7 (196)
6.4 (163)

1.7 (42)
2.1 (54)
2.6 (65)

1.7 (42)
2.1 (54)
2.6 (65)

1.7 (42)
2.1 (54)
2.6 (65)

1.7 (42)
2.1 (54)
2.6 (65)

4.4 (112)
4.7 (119)
4.9 (124)

4.4 (112)
4.7 (119)
4.9 (124)

4.4 (112)
4.7 (119)
4.9 (124)

4.4 (112)
4.7 (119)
4.9 (124)

Valve Model

Number

§



5/2 SINGLE SOLENOID PILOT VALVES

5/2 DOUBLE SOLENOID PILOT VALVES

Avg. Response Constants**

Dimensions

inches (mm)

F

M

Out-Exh.

In-Out

Weight

lb (kg)

Avg.

Cv

ISO

Size

Length

Width

Height

SERIES

W64

POPPET VALVES –

Solenoid Control

1 3

4

2

5

12

14

1 3

4

2

5

12

14

STANDARD SPECIFICATIONS

Solenoids:

Rated for continuous duty.

Standard voltages: 100–110 volts 50 Hz.; 100–120
volts 60 Hz.; 24, 110 volts d.c.

Power Consumption:

8.5 VA inrush; 6 VA holding

on 50 or 60 Hz.; 6 watts on d.c.

Ambient Temperature:

40 to 120° F (4 to 50° C);

High temperature models:

40 to 175° F (4 to 80° C).

Media Temperature:

40 to 175° F (4 to 80° C);

High

temperature models:

40 to 220° F (4 to 105° C).

Flow Media:

Filtered air.

Inlet Pressure:

30 to 150 psig (2 to 10 bar).

Pilot Pressure:

Must be equal to or greater than

inlet pressure.

OPTIONS

Sub-Bases & Manifolds:

Page 14.

Connectors, Electrical:

Page 15.

Regulators, Interposed:

Page 15.

Locking Overrides:

See note below.

§

GM PS-1 models with 3-pin mini-connectors:

See

note below.



Port

Sizes*

1/8 – 3/8
3/8 – 1/2
1/2 – 3/4

1/8 – 3/8
3/8 – 1/2
1/2 – 3/4

1/8 – 3/8
3/8 – 1/2
1/2 – 3/4

1/8 – 3/8
3/8 – 1/2
1/2 – 3/4

5/2 Single Solenoid Pilot Valve

5/2 Double Solenoid Pilot Valve

HIGH TEMPERATURE 5/2 SINGLE SOLENOID PILOT VALVES

HIGH TEMPERATURE 5/2 DOUBLE SOLENOID PILOT VALVES

IMPORTANT NOTE

Please read carefully and thoroughly the

CAUTIONS

on page 23.

**VALVE RESPONSE TIME (msec) = M + (F • V)

Average time required to fill volume V (cubic inches)
to 90% of supply pressure or to exhaust it to 10%
of supply pressure. M and F values are shown in
charts for each valve. See discussion of

Valve

Response Time

on page 22.

§

Models with locking overrides can be ordered by changing the 9th digit of model number to “1”. For example, W6076B2411.



For models with 3-pin mini-connectors that conform to G.M. PS-1 standards, change the 9th digit to “3”. For example, W6076B2431.

* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.

Height of valve with electrical connector installed. Connectors sold separately – see page 15.