Ross Controls 5599_I POPPET SERIES W64 User Manual
Series w64 poppet valves, Solenoid control, Iso 5599/i - drop cord connections

ROSS CONTROLS
®
12
1.0
2.1
4.0
1.0
2.1
4.0
1.0
2.1
4.0
1.0
2.1
4.0
1
2
3
1
2
3
1
2
3
1
2
3
W6476B2401
W6476B3401
W6476B4401
W6476B2407
W6476B3407
W6476B4407
W6476B2402
W6476B3402
W6476B4402
W6476B2408
W6476B3408
W6476B4408
33
33
50
16
16
16
33
33
50
16
16
16
2.9
1.2
0.7
2.9
1.2
0.7
2.9
1.2
0.7
2.9
1.2
0.7
5.9
2.3
1.2
5.6
2.3
1.1
5.9
2.3
1.2
5.6
2.3
1.1
1.3 (0.6)
1.8 (0.8)
2.8 (1.3)
1.8 (0.8)
2.3 (1.1)
3.3 (1.5)
1.3 (0.6)
1.8 (0.8)
2.8 (1.3)
1.8 (0.8)
2.3 (1.1)
3.3 (1.5)
5.6 (142)
6.3 (160)
6.4 (163)
6.9 (175)
7.7 (196)
6.4 (163)
5.6 (142)
6.3 (160)
6.4 (163)
6.9 (175)
7.7 (196)
6.4 (163)
1.7 (42)
2.1 (54)
2.6 (65)
1.7 (42)
2.1 (54)
2.6 (65)
1.7 (42)
2.1 (54)
2.6 (65)
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
4.4 (112)
4.7 (119)
4.9 (124)
4.4 (112)
4.7 (119)
4.9 (124)
4.4 (112)
4.7 (119)
4.9 (124)
Valve Model
Number
§
5/2 SINGLE SOLENOID PILOT VALVES
5/2 DOUBLE SOLENOID PILOT VALVES
Avg. Response Constants**
Dimensions
inches (mm)
F
M
Out-Exh.
In-Out
Weight
lb (kg)
Avg.
Cv
ISO
Size
Length
Width
Height
†
SERIES
W64
POPPET VALVES –
Solenoid Control
1 3
4
2
5
12
14
1 3
4
2
5
12
14
STANDARD SPECIFICATIONS
Solenoids:
Rated for continuous duty.
Standard voltages: 100–110 volts 50 Hz.; 100–120
volts 60 Hz.; 24, 110 volts d.c.
Power Consumption:
8.5 VA inrush; 6 VA holding
on 50 or 60 Hz.; 6 watts on d.c.
Ambient Temperature:
40 to 120° F (4 to 50° C);
High temperature models:
40 to 175° F (4 to 80° C).
Media Temperature:
40 to 175° F (4 to 80° C);
High
temperature models:
40 to 220° F (4 to 105° C).
Flow Media:
Filtered air.
Inlet Pressure:
30 to 150 psig (2 to 10 bar).
Pilot Pressure:
Must be equal to or greater than
inlet pressure.
OPTIONS
Sub-Bases & Manifolds:
Page 14.
Connectors, Electrical:
Page 15.
Regulators, Interposed:
Page 15.
Locking Overrides:
See note below.
§
GM PS-1 models with 3-pin mini-connectors:
See
note below.
Port
Sizes*
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
5/2 Single Solenoid Pilot Valve
5/2 Double Solenoid Pilot Valve
HIGH TEMPERATURE 5/2 SINGLE SOLENOID PILOT VALVES
HIGH TEMPERATURE 5/2 DOUBLE SOLENOID PILOT VALVES
IMPORTANT NOTE
Please read carefully and thoroughly the
CAUTIONS
on page 23.
**VALVE RESPONSE TIME (msec) = M + (F • V)
Average time required to fill volume V (cubic inches)
to 90% of supply pressure or to exhaust it to 10%
of supply pressure. M and F values are shown in
charts for each valve. See discussion of
Valve
Response Time
on page 22.
§
Models with locking overrides can be ordered by changing the 9th digit of model number to “1”. For example, W6076B2411.
For models with 3-pin mini-connectors that conform to G.M. PS-1 standards, change the 9th digit to “3”. For example, W6076B2431.
* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.
†
Height of valve with electrical connector installed. Connectors sold separately – see page 15.
ISO 5599/I - Drop Cord Connections